{"title":"Thermafil闭孔器在牙髓学中的初步研究。","authors":"E Maalouf, J T Sader, S V Attieh","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A clinical study involving 25 patients and a total number of 42 canals was carried out in the department of Endodontics at the Saint-Joseph University of Beirut and in private practice. The use of the Thermafil device seems to be safe due to the carrier manufactured with a stainless steel medical grade, covered with a layer of gutta-percha alpha phase. The clinical results are satisfactory, the technique is simple, fast and efficient, which confirms the results published in the literature. More investigations are necessary to a better evaluation of the system.</p>","PeriodicalId":77616,"journal":{"name":"Revue francaise d'endodontie : publication officielle de la Societe francaise d'endodontie","volume":"10 2","pages":"41-8"},"PeriodicalIF":0.0000,"publicationDate":"1991-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[The Thermafil obturator in endodontics: preliminary study].\",\"authors\":\"E Maalouf, J T Sader, S V Attieh\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A clinical study involving 25 patients and a total number of 42 canals was carried out in the department of Endodontics at the Saint-Joseph University of Beirut and in private practice. The use of the Thermafil device seems to be safe due to the carrier manufactured with a stainless steel medical grade, covered with a layer of gutta-percha alpha phase. The clinical results are satisfactory, the technique is simple, fast and efficient, which confirms the results published in the literature. More investigations are necessary to a better evaluation of the system.</p>\",\"PeriodicalId\":77616,\"journal\":{\"name\":\"Revue francaise d'endodontie : publication officielle de la Societe francaise d'endodontie\",\"volume\":\"10 2\",\"pages\":\"41-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revue francaise d'endodontie : publication officielle de la Societe francaise d'endodontie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revue francaise d'endodontie : publication officielle de la Societe francaise d'endodontie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[The Thermafil obturator in endodontics: preliminary study].
A clinical study involving 25 patients and a total number of 42 canals was carried out in the department of Endodontics at the Saint-Joseph University of Beirut and in private practice. The use of the Thermafil device seems to be safe due to the carrier manufactured with a stainless steel medical grade, covered with a layer of gutta-percha alpha phase. The clinical results are satisfactory, the technique is simple, fast and efficient, which confirms the results published in the literature. More investigations are necessary to a better evaluation of the system.