{"title":"【视网膜外膜扣合手术失败原因】。","authors":"S Clemens, H Busse, K H Emmerich","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In this retrospective study about failures of epiretinal buckling procedures performed over 12 years the causes of failure are analysed. The main ones are: new retinal holes, PVR, wrong localization, and inadequate buckling effect. The aim of this investigation was to find indications of the best technique, with a view to improving the success rate, currently, 80-90%, even further.</p>","PeriodicalId":12437,"journal":{"name":"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft","volume":"88 6","pages":"616-22"},"PeriodicalIF":0.0000,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Reasons for failure after episcleral buckling operation of the retina].\",\"authors\":\"S Clemens, H Busse, K H Emmerich\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this retrospective study about failures of epiretinal buckling procedures performed over 12 years the causes of failure are analysed. The main ones are: new retinal holes, PVR, wrong localization, and inadequate buckling effect. The aim of this investigation was to find indications of the best technique, with a view to improving the success rate, currently, 80-90%, even further.</p>\",\"PeriodicalId\":12437,\"journal\":{\"name\":\"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft\",\"volume\":\"88 6\",\"pages\":\"616-22\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Reasons for failure after episcleral buckling operation of the retina].
In this retrospective study about failures of epiretinal buckling procedures performed over 12 years the causes of failure are analysed. The main ones are: new retinal holes, PVR, wrong localization, and inadequate buckling effect. The aim of this investigation was to find indications of the best technique, with a view to improving the success rate, currently, 80-90%, even further.