Hanbing Qu, Pu Zhao, Bo Wang, Yujian Jia, Yuying Zhang, Yong Wang, Xiaowei Wang
{"title":"VSC-HVDC电缆单端瞬态电流保护方法","authors":"Hanbing Qu, Pu Zhao, Bo Wang, Yujian Jia, Yuying Zhang, Yong Wang, Xiaowei Wang","doi":"10.1109/ICISCAE51034.2020.9236816","DOIUrl":null,"url":null,"abstract":"Based on the boundary characteristic and frequency characteristic of cable, a protection method for VSC-HVDC cable is proposed in this paper, which only uses the single-end transient current signal. First, the frequency components of the currents at the DC-side and AC-side of the DC boundary are extracted by means of S transform, and the magnitude of the high frequency components of DC-side current is employed to detect the fault. Then, the ratio of the magnitude of the high frequency components of the DC- and AC-side currents is calculated to identify the internal fault from the close-up external fault. Finally, the ratio of the high and low frequency components of the DC-side current is calculated to identify the internal fault from the opposite external fault. This protection method is verified on basis of a two-terminal VSC-HVDC model with EMTDC/PSCAD. Various types of faults are simulated, and the simulation results show that this method can identify the internal faults under different conditions rapidly, while can ignore the external faults reliably.","PeriodicalId":355473,"journal":{"name":"2020 IEEE 3rd International Conference on Information Systems and Computer Aided Education (ICISCAE)","volume":"93 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single-End Transient Current Based Protection Method for VSC-HVDC Cable\",\"authors\":\"Hanbing Qu, Pu Zhao, Bo Wang, Yujian Jia, Yuying Zhang, Yong Wang, Xiaowei Wang\",\"doi\":\"10.1109/ICISCAE51034.2020.9236816\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on the boundary characteristic and frequency characteristic of cable, a protection method for VSC-HVDC cable is proposed in this paper, which only uses the single-end transient current signal. First, the frequency components of the currents at the DC-side and AC-side of the DC boundary are extracted by means of S transform, and the magnitude of the high frequency components of DC-side current is employed to detect the fault. Then, the ratio of the magnitude of the high frequency components of the DC- and AC-side currents is calculated to identify the internal fault from the close-up external fault. Finally, the ratio of the high and low frequency components of the DC-side current is calculated to identify the internal fault from the opposite external fault. This protection method is verified on basis of a two-terminal VSC-HVDC model with EMTDC/PSCAD. Various types of faults are simulated, and the simulation results show that this method can identify the internal faults under different conditions rapidly, while can ignore the external faults reliably.\",\"PeriodicalId\":355473,\"journal\":{\"name\":\"2020 IEEE 3rd International Conference on Information Systems and Computer Aided Education (ICISCAE)\",\"volume\":\"93 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 3rd International Conference on Information Systems and Computer Aided Education (ICISCAE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICISCAE51034.2020.9236816\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 3rd International Conference on Information Systems and Computer Aided Education (ICISCAE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISCAE51034.2020.9236816","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Single-End Transient Current Based Protection Method for VSC-HVDC Cable
Based on the boundary characteristic and frequency characteristic of cable, a protection method for VSC-HVDC cable is proposed in this paper, which only uses the single-end transient current signal. First, the frequency components of the currents at the DC-side and AC-side of the DC boundary are extracted by means of S transform, and the magnitude of the high frequency components of DC-side current is employed to detect the fault. Then, the ratio of the magnitude of the high frequency components of the DC- and AC-side currents is calculated to identify the internal fault from the close-up external fault. Finally, the ratio of the high and low frequency components of the DC-side current is calculated to identify the internal fault from the opposite external fault. This protection method is verified on basis of a two-terminal VSC-HVDC model with EMTDC/PSCAD. Various types of faults are simulated, and the simulation results show that this method can identify the internal faults under different conditions rapidly, while can ignore the external faults reliably.