一种扩展卡尔曼滤波电力线干扰抑制器的改进

L. D. Avendaño-Valencia, L. E. Avendaño, J. Ferrero, G. Castellanos-Domínguez
{"title":"一种扩展卡尔曼滤波电力线干扰抑制器的改进","authors":"L. D. Avendaño-Valencia, L. E. Avendaño, J. Ferrero, G. Castellanos-Domínguez","doi":"10.1109/CIC.2007.4745545","DOIUrl":null,"url":null,"abstract":"The powerline interference reduction in ECG records is a challenging problem which is still open for research. The powerline signal, measured directly from the transmission line may have amplitude, phase and frequency variations. These reasons make the classical filtering methods sub-optimal in the powerline interference reduction. We propose a tracking method based on Kalman filtering which uses an state space model for the noisy signal and allows adequate discrimination between the ECG signal and the perturbation, even during non-stationarities. The parameters of this algorithm are optimized via genetic algorithms, obtaining a set of values that give it a mean correlation index on the QT database over 0,99.","PeriodicalId":406683,"journal":{"name":"2007 Computers in Cardiology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"31","resultStr":"{\"title\":\"Improvement of an extended Kalman filter power line interference suppressor for ECG signals\",\"authors\":\"L. D. Avendaño-Valencia, L. E. Avendaño, J. Ferrero, G. Castellanos-Domínguez\",\"doi\":\"10.1109/CIC.2007.4745545\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The powerline interference reduction in ECG records is a challenging problem which is still open for research. The powerline signal, measured directly from the transmission line may have amplitude, phase and frequency variations. These reasons make the classical filtering methods sub-optimal in the powerline interference reduction. We propose a tracking method based on Kalman filtering which uses an state space model for the noisy signal and allows adequate discrimination between the ECG signal and the perturbation, even during non-stationarities. The parameters of this algorithm are optimized via genetic algorithms, obtaining a set of values that give it a mean correlation index on the QT database over 0,99.\",\"PeriodicalId\":406683,\"journal\":{\"name\":\"2007 Computers in Cardiology\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"31\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Computers in Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2007.4745545\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Computers in Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2007.4745545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31

摘要

减少电力线对心电记录的干扰是一个具有挑战性的问题,仍有待进一步研究。直接从传输线测得的电力线信号可能有幅度、相位和频率的变化。这些原因使得传统滤波方法在降低电力线干扰方面不是最优的。我们提出了一种基于卡尔曼滤波的跟踪方法,该方法对噪声信号使用状态空间模型,即使在非平稳状态下也能充分区分心电信号和扰动。该算法的参数通过遗传算法进行优化,得到一组值,使其在QT数据库上的平均相关指数大于0,99。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improvement of an extended Kalman filter power line interference suppressor for ECG signals
The powerline interference reduction in ECG records is a challenging problem which is still open for research. The powerline signal, measured directly from the transmission line may have amplitude, phase and frequency variations. These reasons make the classical filtering methods sub-optimal in the powerline interference reduction. We propose a tracking method based on Kalman filtering which uses an state space model for the noisy signal and allows adequate discrimination between the ECG signal and the perturbation, even during non-stationarities. The parameters of this algorithm are optimized via genetic algorithms, obtaining a set of values that give it a mean correlation index on the QT database over 0,99.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信