结合网格、体积和流线表示在CT结肠镜中检测息肉

V. F. V. Ravesteijn, Lingxiao Zhao, C. Botha, F. Post, F. Vos, L. Vliet
{"title":"结合网格、体积和流线表示在CT结肠镜中检测息肉","authors":"V. F. V. Ravesteijn, Lingxiao Zhao, C. Botha, F. Post, F. Vos, L. Vliet","doi":"10.1109/ISBI.2009.5193200","DOIUrl":null,"url":null,"abstract":"CT colonography is a screening technique for adenomatous colorectal polyps, which are important precursors to colon cancer. Computer aided detection (CAD) systems are developed to assist radiologists. We present a CAD system that substantially reduces false positives while keeping the sensitivity high. Hereto, we combine protrusion measures derived from the solution of a non-linear partial differential equation (PDE) applied to both an explicit mesh and an implicit volumetric representation of the colon wall. The shape of the protruding elements is efficiently described via a technique from data visualization based on curvature streamlines. A low-complex pattern recognition system based on an intuitive feature from the aforementioned representations improves performance to less than 1.6 false positives per scan at 92% sensitivity per polyp.","PeriodicalId":272938,"journal":{"name":"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Combining mesh, volume, and streamline representations for polyp detection in CT colonography\",\"authors\":\"V. F. V. Ravesteijn, Lingxiao Zhao, C. Botha, F. Post, F. Vos, L. Vliet\",\"doi\":\"10.1109/ISBI.2009.5193200\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"CT colonography is a screening technique for adenomatous colorectal polyps, which are important precursors to colon cancer. Computer aided detection (CAD) systems are developed to assist radiologists. We present a CAD system that substantially reduces false positives while keeping the sensitivity high. Hereto, we combine protrusion measures derived from the solution of a non-linear partial differential equation (PDE) applied to both an explicit mesh and an implicit volumetric representation of the colon wall. The shape of the protruding elements is efficiently described via a technique from data visualization based on curvature streamlines. A low-complex pattern recognition system based on an intuitive feature from the aforementioned representations improves performance to less than 1.6 false positives per scan at 92% sensitivity per polyp.\",\"PeriodicalId\":272938,\"journal\":{\"name\":\"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBI.2009.5193200\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2009.5193200","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

CT结肠镜检查是一种筛查结直肠腺瘤性息肉的技术,它是结肠癌的重要前兆。计算机辅助检测(CAD)系统的开发是为了协助放射科医生。我们提出了一个CAD系统,大大减少误报,同时保持高灵敏度。在此,我们结合了从非线性偏微分方程(PDE)的解中导出的突出度量,应用于显式网格和隐式结肠壁的体积表示。通过基于曲率流线的数据可视化技术有效地描述了突出元素的形状。基于上述表示的直观特征的低复杂性模式识别系统将性能提高到每次扫描低于1.6个假阳性,每个息肉的灵敏度为92%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Combining mesh, volume, and streamline representations for polyp detection in CT colonography
CT colonography is a screening technique for adenomatous colorectal polyps, which are important precursors to colon cancer. Computer aided detection (CAD) systems are developed to assist radiologists. We present a CAD system that substantially reduces false positives while keeping the sensitivity high. Hereto, we combine protrusion measures derived from the solution of a non-linear partial differential equation (PDE) applied to both an explicit mesh and an implicit volumetric representation of the colon wall. The shape of the protruding elements is efficiently described via a technique from data visualization based on curvature streamlines. A low-complex pattern recognition system based on an intuitive feature from the aforementioned representations improves performance to less than 1.6 false positives per scan at 92% sensitivity per polyp.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信