填充柱气相色谱法测定含多氯联苯的人血清中灭雷克斯的含量。

M P Korver, V W Burse, L L Needham, V E Green, D L Gray, M A Rouse, T L Shelly, B K Mortensen
{"title":"填充柱气相色谱法测定含多氯联苯的人血清中灭雷克斯的含量。","authors":"M P Korver,&nbsp;V W Burse,&nbsp;L L Needham,&nbsp;V E Green,&nbsp;D L Gray,&nbsp;M A Rouse,&nbsp;T L Shelly,&nbsp;B K Mortensen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An analytical method has been developed that uses electron capture/gas-liquid chromatography to determine Mirex in serum containing polychlorinated biphenyls (PCBs) (Aroclor 1260). With this method, 0.2 ppb Mirex can be determined in 4 mL serum that also contains 10 ppb PCBs. The method provides approximately 70% recovery of Mirex at 1.0 and 3.5 ppb. The coefficients of variation are 4.5 and 4.6% at 1.0 and 3.5 ppb, respectively. In a cooperative study with the Ohio Department of Health, the Centers for Disease Control used this method to determine the extent of exposure of Salem, OH, residents to Mirex. Confirmation of Mirex was obtained by using high resolution gas chromatography and high resolution mass spectrometry.</p>","PeriodicalId":14752,"journal":{"name":"Journal - Association of Official Analytical Chemists","volume":"74 5","pages":"875-7"},"PeriodicalIF":0.0000,"publicationDate":"1991-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of Mirex in human blood serum containing polychlorinated biphenyls by using packed column gas chromatography.\",\"authors\":\"M P Korver,&nbsp;V W Burse,&nbsp;L L Needham,&nbsp;V E Green,&nbsp;D L Gray,&nbsp;M A Rouse,&nbsp;T L Shelly,&nbsp;B K Mortensen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An analytical method has been developed that uses electron capture/gas-liquid chromatography to determine Mirex in serum containing polychlorinated biphenyls (PCBs) (Aroclor 1260). With this method, 0.2 ppb Mirex can be determined in 4 mL serum that also contains 10 ppb PCBs. The method provides approximately 70% recovery of Mirex at 1.0 and 3.5 ppb. The coefficients of variation are 4.5 and 4.6% at 1.0 and 3.5 ppb, respectively. In a cooperative study with the Ohio Department of Health, the Centers for Disease Control used this method to determine the extent of exposure of Salem, OH, residents to Mirex. Confirmation of Mirex was obtained by using high resolution gas chromatography and high resolution mass spectrometry.</p>\",\"PeriodicalId\":14752,\"journal\":{\"name\":\"Journal - Association of Official Analytical Chemists\",\"volume\":\"74 5\",\"pages\":\"875-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal - Association of Official Analytical Chemists\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal - Association of Official Analytical Chemists","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

开发了一种电子捕获/气液色谱法测定含多氯联苯(PCBs) (Aroclor 1260)血清中咪雷克斯的分析方法。使用该方法,在含有10 ppb多氯联苯的4 mL血清中可以测定0.2 ppb的Mirex。该方法在1.0和3.5 ppb下可提供约70%的Mirex回收率。在1.0和3.5 ppb下,变异系数分别为4.5和4.6%。在与俄亥俄州卫生部的一项合作研究中,疾病控制中心使用这种方法来确定俄亥俄州塞勒姆居民对米雷克斯的暴露程度。采用高分辨率气相色谱法和高分辨率质谱法对Mirex进行确证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of Mirex in human blood serum containing polychlorinated biphenyls by using packed column gas chromatography.

An analytical method has been developed that uses electron capture/gas-liquid chromatography to determine Mirex in serum containing polychlorinated biphenyls (PCBs) (Aroclor 1260). With this method, 0.2 ppb Mirex can be determined in 4 mL serum that also contains 10 ppb PCBs. The method provides approximately 70% recovery of Mirex at 1.0 and 3.5 ppb. The coefficients of variation are 4.5 and 4.6% at 1.0 and 3.5 ppb, respectively. In a cooperative study with the Ohio Department of Health, the Centers for Disease Control used this method to determine the extent of exposure of Salem, OH, residents to Mirex. Confirmation of Mirex was obtained by using high resolution gas chromatography and high resolution mass spectrometry.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信