{"title":"空压机轴断裂失效分析","authors":"Mingxian Zhang, Fa-cai Ren, Bin Ren, Shaoyi Hou","doi":"10.1109/ICEDME50972.2020.00042","DOIUrl":null,"url":null,"abstract":"A shaft of the air compressor broke during use. By means of scanning electron microscope analysis, metallographic analysis and energy spectrum analysis, the fracture reason of the shaft was analyzed systematically. The results show that the broken shaft material is not subject to solution treatment or the solution treatment is unqualified. The fracture of the shaft is caused by a large force in a short time.","PeriodicalId":155375,"journal":{"name":"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fracture Failure Analysis on Air Compressor Shaft\",\"authors\":\"Mingxian Zhang, Fa-cai Ren, Bin Ren, Shaoyi Hou\",\"doi\":\"10.1109/ICEDME50972.2020.00042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A shaft of the air compressor broke during use. By means of scanning electron microscope analysis, metallographic analysis and energy spectrum analysis, the fracture reason of the shaft was analyzed systematically. The results show that the broken shaft material is not subject to solution treatment or the solution treatment is unqualified. The fracture of the shaft is caused by a large force in a short time.\",\"PeriodicalId\":155375,\"journal\":{\"name\":\"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEDME50972.2020.00042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Electron Device and Mechanical Engineering (ICEDME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEDME50972.2020.00042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A shaft of the air compressor broke during use. By means of scanning electron microscope analysis, metallographic analysis and energy spectrum analysis, the fracture reason of the shaft was analyzed systematically. The results show that the broken shaft material is not subject to solution treatment or the solution treatment is unqualified. The fracture of the shaft is caused by a large force in a short time.