{"title":"双馈感应发电机在机电振荡中的响应特性分析","authors":"Xiaoqiang Wei, Feng Qi, Wenbin Wu, Deyou Yang","doi":"10.1109/ICPET55165.2022.9918384","DOIUrl":null,"url":null,"abstract":"As the Doubly Fed Induction Generator (DFIG) is connected to the power system, the electromechanical oscillation characteristics of the traditional power system have changed. To study the influence of DFIG access on the low-frequency oscillation of traditional power systems, this paper uses open-loop analysis to separate the influence of DFIG, establishes DFIG and traditional power system open-loop model, and uses frequency domain analysis to analyze DFIG access to the traditional system. The impact of open-loop is analyzed by analyzing the influence of DFIG power loop parameters and access location and access on the electromechanical oscillation response characteristics of traditional systems. The feasibility of the method is verified by simulation, which can reflect the DFIG response to the rest of the system's electromechanical oscillations. This method can be used to analyze the reasonable parameter settings, access capacity, and access mode of DFIG.","PeriodicalId":355634,"journal":{"name":"2022 4th International Conference on Power and Energy Technology (ICPET)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Response Characteristics of Doubly Fed Induction Generator in Electromechanical Oscillation\",\"authors\":\"Xiaoqiang Wei, Feng Qi, Wenbin Wu, Deyou Yang\",\"doi\":\"10.1109/ICPET55165.2022.9918384\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As the Doubly Fed Induction Generator (DFIG) is connected to the power system, the electromechanical oscillation characteristics of the traditional power system have changed. To study the influence of DFIG access on the low-frequency oscillation of traditional power systems, this paper uses open-loop analysis to separate the influence of DFIG, establishes DFIG and traditional power system open-loop model, and uses frequency domain analysis to analyze DFIG access to the traditional system. The impact of open-loop is analyzed by analyzing the influence of DFIG power loop parameters and access location and access on the electromechanical oscillation response characteristics of traditional systems. The feasibility of the method is verified by simulation, which can reflect the DFIG response to the rest of the system's electromechanical oscillations. This method can be used to analyze the reasonable parameter settings, access capacity, and access mode of DFIG.\",\"PeriodicalId\":355634,\"journal\":{\"name\":\"2022 4th International Conference on Power and Energy Technology (ICPET)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 4th International Conference on Power and Energy Technology (ICPET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPET55165.2022.9918384\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 4th International Conference on Power and Energy Technology (ICPET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPET55165.2022.9918384","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

双馈感应发电机(DFIG)接入电力系统后,改变了传统电力系统的机电振荡特性。为了研究DFIG接入对传统电力系统低频振荡的影响,本文采用开环分析方法分离DFIG的影响,建立DFIG与传统电力系统的开环模型,并采用频域分析方法分析DFIG接入对传统电力系统的影响。通过分析DFIG电源回路参数、接入位置和接入对传统系统机电振荡响应特性的影响,分析开环的影响。通过仿真验证了该方法的可行性,该方法能够反映DFIG对系统其余机电振荡的响应。该方法可用于分析DFIG的合理参数设置、接入容量和接入方式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of Response Characteristics of Doubly Fed Induction Generator in Electromechanical Oscillation
As the Doubly Fed Induction Generator (DFIG) is connected to the power system, the electromechanical oscillation characteristics of the traditional power system have changed. To study the influence of DFIG access on the low-frequency oscillation of traditional power systems, this paper uses open-loop analysis to separate the influence of DFIG, establishes DFIG and traditional power system open-loop model, and uses frequency domain analysis to analyze DFIG access to the traditional system. The impact of open-loop is analyzed by analyzing the influence of DFIG power loop parameters and access location and access on the electromechanical oscillation response characteristics of traditional systems. The feasibility of the method is verified by simulation, which can reflect the DFIG response to the rest of the system's electromechanical oscillations. This method can be used to analyze the reasonable parameter settings, access capacity, and access mode of DFIG.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信