猪和人腰椎间盘的动态和初始蠕变响应的比较

Â. Araújo, N. Peixinho, A. Pinho, J. Claro
{"title":"猪和人腰椎间盘的动态和初始蠕变响应的比较","authors":"Â. Araújo, N. Peixinho, A. Pinho, J. Claro","doi":"10.1109/ENBENG.2015.7088868","DOIUrl":null,"url":null,"abstract":"The study of mechanical properties of intervertebral disc (IVD) is important for the evaluation of disc implants. To determine these properties, several animal spine models were used. The goal of this work is to determine and compare the dynamic stiffness coefficient (Kd) and initial creep behavior of porcine intervertebral disc with the human ones. Porcine lumbar “motion segments” were subjected to 1200 cycles of axial compressive loading at 1 Hz, and a mean load of 500 N. The results were fitted with a mathematical model. The Kd values are in same magnitude as the previously reported for human. The model showed a good adjust to the initial creep behavior and the obtained parameters present the same magnitude as the human discs, with exception of time constant. This work revealed that porcine MS is an interesting model to study both the dynamic behavior and initial creep response of human disc.","PeriodicalId":285567,"journal":{"name":"2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Comparison between the dynamic and initial creep response of porcine and human lumbar intervertebral discs\",\"authors\":\"Â. Araújo, N. Peixinho, A. Pinho, J. Claro\",\"doi\":\"10.1109/ENBENG.2015.7088868\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study of mechanical properties of intervertebral disc (IVD) is important for the evaluation of disc implants. To determine these properties, several animal spine models were used. The goal of this work is to determine and compare the dynamic stiffness coefficient (Kd) and initial creep behavior of porcine intervertebral disc with the human ones. Porcine lumbar “motion segments” were subjected to 1200 cycles of axial compressive loading at 1 Hz, and a mean load of 500 N. The results were fitted with a mathematical model. The Kd values are in same magnitude as the previously reported for human. The model showed a good adjust to the initial creep behavior and the obtained parameters present the same magnitude as the human discs, with exception of time constant. This work revealed that porcine MS is an interesting model to study both the dynamic behavior and initial creep response of human disc.\",\"PeriodicalId\":285567,\"journal\":{\"name\":\"2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ENBENG.2015.7088868\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ENBENG.2015.7088868","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

椎间盘力学性能的研究对椎间盘植入物的评价具有重要意义。为了确定这些特性,使用了几种动物脊柱模型。这项工作的目的是确定和比较猪椎间盘与人椎间盘的动态刚度系数(Kd)和初始蠕变行为。猪腰部“运动节段”承受1200次轴向压缩载荷,频率为1 Hz,平均载荷为500 n。Kd值与先前报道的人类相同。模型对初始蠕变行为有较好的调整,所得参数除时间常数外,与真人盘的大小相同。结果表明,猪多发性硬化症是研究人类椎间盘动力学行为和初始蠕变响应的一个有趣的模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison between the dynamic and initial creep response of porcine and human lumbar intervertebral discs
The study of mechanical properties of intervertebral disc (IVD) is important for the evaluation of disc implants. To determine these properties, several animal spine models were used. The goal of this work is to determine and compare the dynamic stiffness coefficient (Kd) and initial creep behavior of porcine intervertebral disc with the human ones. Porcine lumbar “motion segments” were subjected to 1200 cycles of axial compressive loading at 1 Hz, and a mean load of 500 N. The results were fitted with a mathematical model. The Kd values are in same magnitude as the previously reported for human. The model showed a good adjust to the initial creep behavior and the obtained parameters present the same magnitude as the human discs, with exception of time constant. This work revealed that porcine MS is an interesting model to study both the dynamic behavior and initial creep response of human disc.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信