{"title":"设计一种自动消毒剂混合工具(COVID-19流行预防病例研究)","authors":"Harianto Bangun, Agus Ulinuha","doi":"10.23917/emitor.v22i1.15710","DOIUrl":null,"url":null,"abstract":"The Coronavirus pandemic or Covid-19 caused by Corona Virus which spread widely in 2020 is very dangerous because it threatens the safety of humanity by means of very fast and easy transmission. One of the most popular prevention efforts is the use of disinfectants to eradicate the corona virus. This study examines an automatic disinfectant mixer which uses a flow meter sensor to measure the flowing solution and the volume of the solution. In addition, this tool also uses a solenoid valve as a cover and automatic valve opening that regulates the running of water. This automatic disinfectant mixer is controlled by the Atmega328P microcontroller at Arduino nano board. In this study the capacity is limited from 1 liter to 5 liters of disinfectant with the composition per liter of disinfectant consisting of 905 mL of water and 95 mL of sodium hypochlorite, while the DC motor will stir for 2 seconds. The results of testing this tool, the flow meter can read the flow and the volume of liquid, but there is an error in the calibration of the flow meter sensor of 0.21 to 1.8%, while in testing the disinfectant volume capacity, this tool can mix disinfectants from water and sodium hypochlorite to a maximum volume capacity of 5 liters, but there is a difference of up to 100-170 mL, between the specified disinfectant capacity and the disinfectant volume contained in the measuring cup.","PeriodicalId":431304,"journal":{"name":"Emitor: Jurnal Teknik Elektro","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"RANCANG BANGUN ALAT PENCAMPUR DESINFEKTAN OTOMATIS (STUDI KASUS PENCEGAHAN PANDEMI COVID-19)\",\"authors\":\"Harianto Bangun, Agus Ulinuha\",\"doi\":\"10.23917/emitor.v22i1.15710\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Coronavirus pandemic or Covid-19 caused by Corona Virus which spread widely in 2020 is very dangerous because it threatens the safety of humanity by means of very fast and easy transmission. One of the most popular prevention efforts is the use of disinfectants to eradicate the corona virus. This study examines an automatic disinfectant mixer which uses a flow meter sensor to measure the flowing solution and the volume of the solution. In addition, this tool also uses a solenoid valve as a cover and automatic valve opening that regulates the running of water. This automatic disinfectant mixer is controlled by the Atmega328P microcontroller at Arduino nano board. In this study the capacity is limited from 1 liter to 5 liters of disinfectant with the composition per liter of disinfectant consisting of 905 mL of water and 95 mL of sodium hypochlorite, while the DC motor will stir for 2 seconds. The results of testing this tool, the flow meter can read the flow and the volume of liquid, but there is an error in the calibration of the flow meter sensor of 0.21 to 1.8%, while in testing the disinfectant volume capacity, this tool can mix disinfectants from water and sodium hypochlorite to a maximum volume capacity of 5 liters, but there is a difference of up to 100-170 mL, between the specified disinfectant capacity and the disinfectant volume contained in the measuring cup.\",\"PeriodicalId\":431304,\"journal\":{\"name\":\"Emitor: Jurnal Teknik Elektro\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Emitor: Jurnal Teknik Elektro\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23917/emitor.v22i1.15710\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Emitor: Jurnal Teknik Elektro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23917/emitor.v22i1.15710","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

2020年广泛传播的冠状病毒引起的冠状病毒大流行或Covid-19非常危险,因为它以非常快速和容易的传播方式威胁着人类的安全。最流行的预防措施之一是使用消毒剂根除冠状病毒。本研究研究了一种自动消毒混合器,该混合器使用流量计传感器来测量流动的溶液和溶液的体积。此外,该工具还使用电磁阀作为阀盖和自动阀开度来调节水的运行。该自动消毒混频器由Arduino纳米板上的Atmega328P微控制器控制。在本研究中,容量限制为1升至5升消毒剂,每升消毒剂的成分为905ml水和95ml次氯酸钠,同时直流电机搅拌2秒。测试这个工具的结果,流量计可以读取流和液体的体积,但有一个错误的校准流量计传感器0.21到1.8%,而在测试消毒剂体积容量,这个工具可以从水和次氯酸钠消毒剂混合到一个5升的最大体积容量,但有一个不同的100 - 170毫升,之间的消毒剂消毒能力和指定卷包含在量杯。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
RANCANG BANGUN ALAT PENCAMPUR DESINFEKTAN OTOMATIS (STUDI KASUS PENCEGAHAN PANDEMI COVID-19)
The Coronavirus pandemic or Covid-19 caused by Corona Virus which spread widely in 2020 is very dangerous because it threatens the safety of humanity by means of very fast and easy transmission. One of the most popular prevention efforts is the use of disinfectants to eradicate the corona virus. This study examines an automatic disinfectant mixer which uses a flow meter sensor to measure the flowing solution and the volume of the solution. In addition, this tool also uses a solenoid valve as a cover and automatic valve opening that regulates the running of water. This automatic disinfectant mixer is controlled by the Atmega328P microcontroller at Arduino nano board. In this study the capacity is limited from 1 liter to 5 liters of disinfectant with the composition per liter of disinfectant consisting of 905 mL of water and 95 mL of sodium hypochlorite, while the DC motor will stir for 2 seconds. The results of testing this tool, the flow meter can read the flow and the volume of liquid, but there is an error in the calibration of the flow meter sensor of 0.21 to 1.8%, while in testing the disinfectant volume capacity, this tool can mix disinfectants from water and sodium hypochlorite to a maximum volume capacity of 5 liters, but there is a difference of up to 100-170 mL, between the specified disinfectant capacity and the disinfectant volume contained in the measuring cup.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信