{"title":"CMS外部跟踪器的运行和性能","authors":"E. Butz","doi":"10.22323/1.309.0013","DOIUrl":null,"url":null,"abstract":"The CMS Silicon Strip Tracker with its more than 15000 silicon modules and 200 m$^2$ of active silicon area has been running together with the other subsystems of CMS for several years. We present the performance of the detector in the LHC Run 2 data taking. Results for signal-to-noise, hit efficiency and single hit resolution will be presented. We review the behavior of the system when running at beyond-design instantaneous luminosity and describe challenges observed under these conditions. The evolution of detector parameters under the influence of radiation damage are presented and compared to simulations.","PeriodicalId":325789,"journal":{"name":"Proceedings of The 26th International Workshop on Vertex Detectors — PoS(Vertex 2017)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Operation and Performance of the CMS outer tracker\",\"authors\":\"E. Butz\",\"doi\":\"10.22323/1.309.0013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The CMS Silicon Strip Tracker with its more than 15000 silicon modules and 200 m$^2$ of active silicon area has been running together with the other subsystems of CMS for several years. We present the performance of the detector in the LHC Run 2 data taking. Results for signal-to-noise, hit efficiency and single hit resolution will be presented. We review the behavior of the system when running at beyond-design instantaneous luminosity and describe challenges observed under these conditions. The evolution of detector parameters under the influence of radiation damage are presented and compared to simulations.\",\"PeriodicalId\":325789,\"journal\":{\"name\":\"Proceedings of The 26th International Workshop on Vertex Detectors — PoS(Vertex 2017)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of The 26th International Workshop on Vertex Detectors — PoS(Vertex 2017)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22323/1.309.0013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of The 26th International Workshop on Vertex Detectors — PoS(Vertex 2017)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22323/1.309.0013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
CMS硅条跟踪器拥有超过15000个硅模块和2亿美元的有效硅面积,已经与CMS的其他子系统一起运行了好几年。介绍了该探测器在LHC Run 2数据采集中的性能。将给出信噪比、命中效率和单命中分辨率的结果。我们回顾了系统在超出设计的瞬时亮度下运行时的行为,并描述了在这些条件下观察到的挑战。给出了探测器参数在辐射损伤影响下的演化规律,并与仿真结果进行了比较。
Operation and Performance of the CMS outer tracker
The CMS Silicon Strip Tracker with its more than 15000 silicon modules and 200 m$^2$ of active silicon area has been running together with the other subsystems of CMS for several years. We present the performance of the detector in the LHC Run 2 data taking. Results for signal-to-noise, hit efficiency and single hit resolution will be presented. We review the behavior of the system when running at beyond-design instantaneous luminosity and describe challenges observed under these conditions. The evolution of detector parameters under the influence of radiation damage are presented and compared to simulations.