{"title":"有效生物阻抗谱法评价人体细胞水室","authors":"R. Fiorini, G. Dacquino, G. Arrigo, C.L. Selicato, G. D’Amico","doi":"10.1109/ICBEM.1998.666463","DOIUrl":null,"url":null,"abstract":"The traditional Cole or CFC basic model might offer too coarse estimations in personalized haemodialytic treatment. To take advantage of the full information content offered by BIS instrumentation the traditional CFC model can be extended into a more convenient model: the Extended CFC (ECFC) model. The ECFC model is used to fit raw bioimpedance measurements to increase the overall estimation accuracy of Resistance and Reactance terms. An experimental comparison between CPC, ECFC model simulations, and experimental data is presented. Experimental results show that higher accuracies (at least a tenfold improvement) over the traditional CFC model are easily achieved.","PeriodicalId":213764,"journal":{"name":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Effective bioimpedance spectroscopy method for evaluation of body cell water compartments\",\"authors\":\"R. Fiorini, G. Dacquino, G. Arrigo, C.L. Selicato, G. D’Amico\",\"doi\":\"10.1109/ICBEM.1998.666463\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The traditional Cole or CFC basic model might offer too coarse estimations in personalized haemodialytic treatment. To take advantage of the full information content offered by BIS instrumentation the traditional CFC model can be extended into a more convenient model: the Extended CFC (ECFC) model. The ECFC model is used to fit raw bioimpedance measurements to increase the overall estimation accuracy of Resistance and Reactance terms. An experimental comparison between CPC, ECFC model simulations, and experimental data is presented. Experimental results show that higher accuracies (at least a tenfold improvement) over the traditional CFC model are easily achieved.\",\"PeriodicalId\":213764,\"journal\":{\"name\":\"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBEM.1998.666463\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBEM.1998.666463","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

传统的Cole或CFC基本模型可能在个性化血液透析治疗中提供过于粗糙的估计。为了利用BIS仪器提供的全部信息内容,可以将传统的CFC模型扩展为更方便的模型:扩展CFC (ECFC)模型。ECFC模型用于拟合原始生物阻抗测量,以提高电阻和电抗项的整体估计精度。对CPC、ECFC模型的模拟结果与实验数据进行了对比。实验结果表明,与传统的CFC模型相比,该模型可以很容易地实现更高的精度(至少提高十倍)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effective bioimpedance spectroscopy method for evaluation of body cell water compartments
The traditional Cole or CFC basic model might offer too coarse estimations in personalized haemodialytic treatment. To take advantage of the full information content offered by BIS instrumentation the traditional CFC model can be extended into a more convenient model: the Extended CFC (ECFC) model. The ECFC model is used to fit raw bioimpedance measurements to increase the overall estimation accuracy of Resistance and Reactance terms. An experimental comparison between CPC, ECFC model simulations, and experimental data is presented. Experimental results show that higher accuracies (at least a tenfold improvement) over the traditional CFC model are easily achieved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信