{"title":"通过开口连通的两个房间中冲击波的传播","authors":"I. Sochet, K. Gault, L. Hakenholz","doi":"10.5772/INTECHOPEN.87190","DOIUrl":null,"url":null,"abstract":"Confined explosions represent a serious safety hazard as significant damage to humans and structures is observed, unlike in free-field explosions. An experimental small-scale study investigated the blast wave in a single-story building. The blast waves were generated by the detonation of a gaseous charge. The building was divided into two rooms by a movable wall which could be positioned at three different locations. The presence of an opening in this movable wall means that two rooms were considered: a transmitter room (TR) and a receptor room (RR). The configuration without the movable wall was also studied. Pressure profiles recorded with pressure gauges at ground level and on the wall presented numerous reflections. The damage effects were severe since the maximum overpressure never fell below 0.2 bar. Although this study is limited to a small scale and gaseous detonation charge, the results can be applied to a large scale and for a TNT charge.","PeriodicalId":123276,"journal":{"name":"Direct Numerical Simulations - An Introduction and Applications","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Propagation of Shock Waves in Two Rooms Communicating through an Opening\",\"authors\":\"I. Sochet, K. Gault, L. Hakenholz\",\"doi\":\"10.5772/INTECHOPEN.87190\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Confined explosions represent a serious safety hazard as significant damage to humans and structures is observed, unlike in free-field explosions. An experimental small-scale study investigated the blast wave in a single-story building. The blast waves were generated by the detonation of a gaseous charge. The building was divided into two rooms by a movable wall which could be positioned at three different locations. The presence of an opening in this movable wall means that two rooms were considered: a transmitter room (TR) and a receptor room (RR). The configuration without the movable wall was also studied. Pressure profiles recorded with pressure gauges at ground level and on the wall presented numerous reflections. The damage effects were severe since the maximum overpressure never fell below 0.2 bar. Although this study is limited to a small scale and gaseous detonation charge, the results can be applied to a large scale and for a TNT charge.\",\"PeriodicalId\":123276,\"journal\":{\"name\":\"Direct Numerical Simulations - An Introduction and Applications\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Direct Numerical Simulations - An Introduction and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5772/INTECHOPEN.87190\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Direct Numerical Simulations - An Introduction and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5772/INTECHOPEN.87190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

与自由场爆炸不同,密闭爆炸会对人体和建筑物造成严重损害,因此具有严重的安全隐患。小型实验研究了单层建筑中的爆炸冲击波。爆炸波是由气体炸药爆炸产生的。建筑被可移动的墙分为两个房间,可以定位在三个不同的位置。在这个可移动的墙上有一个开口,这意味着考虑了两个房间:一个发送室(TR)和一个接收室(RR)。对无活动壁面的结构进行了研究。在地面和墙上用压力表记录的压力剖面显示了许多反射。由于最大超压从未低于0.2 bar,因此损坏效果非常严重。虽然本研究仅限于小型气体爆轰药,但其结果可应用于大型TNT爆轰药。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Propagation of Shock Waves in Two Rooms Communicating through an Opening
Confined explosions represent a serious safety hazard as significant damage to humans and structures is observed, unlike in free-field explosions. An experimental small-scale study investigated the blast wave in a single-story building. The blast waves were generated by the detonation of a gaseous charge. The building was divided into two rooms by a movable wall which could be positioned at three different locations. The presence of an opening in this movable wall means that two rooms were considered: a transmitter room (TR) and a receptor room (RR). The configuration without the movable wall was also studied. Pressure profiles recorded with pressure gauges at ground level and on the wall presented numerous reflections. The damage effects were severe since the maximum overpressure never fell below 0.2 bar. Although this study is limited to a small scale and gaseous detonation charge, the results can be applied to a large scale and for a TNT charge.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信