半消声室与全消声室场强的合理比较

Ruoting Chang
{"title":"半消声室与全消声室场强的合理比较","authors":"Ruoting Chang","doi":"10.1109/CEEM.2003.238541","DOIUrl":null,"url":null,"abstract":"In this article the validation of a fully anechoic chamber adopted to perform an EMI compliance test is explored by conducting test and theoretical analysis, and a preferred limit which is correlated to the present limit based on OATS is provided.","PeriodicalId":129734,"journal":{"name":"Asia-Pacific Conference on Environmental Electromagnetics, 2003. CEEM 2003. Proceedings.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rational comparison of field strength between semi-anechoic chamber and fully anechoic chamber\",\"authors\":\"Ruoting Chang\",\"doi\":\"10.1109/CEEM.2003.238541\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article the validation of a fully anechoic chamber adopted to perform an EMI compliance test is explored by conducting test and theoretical analysis, and a preferred limit which is correlated to the present limit based on OATS is provided.\",\"PeriodicalId\":129734,\"journal\":{\"name\":\"Asia-Pacific Conference on Environmental Electromagnetics, 2003. CEEM 2003. Proceedings.\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asia-Pacific Conference on Environmental Electromagnetics, 2003. CEEM 2003. Proceedings.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEEM.2003.238541\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Conference on Environmental Electromagnetics, 2003. CEEM 2003. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEM.2003.238541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文通过试验和理论分析,探讨了用于电磁干扰符合性测试的全消声室的有效性,并给出了与目前基于OATS的极限相关的优选极限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rational comparison of field strength between semi-anechoic chamber and fully anechoic chamber
In this article the validation of a fully anechoic chamber adopted to perform an EMI compliance test is explored by conducting test and theoretical analysis, and a preferred limit which is correlated to the present limit based on OATS is provided.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信