屏蔽室内60ghz无线电信道测量与建模

M. Kyrö, J. Simola, K. Haneda, S. Ranvier, P. Vainikainen, K. Takizawa
{"title":"屏蔽室内60ghz无线电信道测量与建模","authors":"M. Kyrö, J. Simola, K. Haneda, S. Ranvier, P. Vainikainen, K. Takizawa","doi":"10.1109/VETECS.2010.5494120","DOIUrl":null,"url":null,"abstract":"This report describes results from 60 GHz channel measurements and modelling in a shielded room. Final goal of this work is to investigate potential and feasibility of 60 GHz radios for very-high-data-rate short-range communications in medical applications. The measurement in a shielded room is meaningful for studying propagation characteristics in medical applications, since real surgery rooms are typically shielded. One particular usage scenario, i.e., real-time video streaming for ultrasonic imaging, was considered, where the antenna settings were adjusted to the usage scenario accordingly. Link budget and delay domain multipath characteristics were analyzed and modelled. Finally, model parameters that fit the measured power delay profiles were given.","PeriodicalId":325246,"journal":{"name":"2010 IEEE 71st Vehicular Technology Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"60 GHz Radio Channel Measurements and Modeling in a Shielded Room\",\"authors\":\"M. Kyrö, J. Simola, K. Haneda, S. Ranvier, P. Vainikainen, K. Takizawa\",\"doi\":\"10.1109/VETECS.2010.5494120\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This report describes results from 60 GHz channel measurements and modelling in a shielded room. Final goal of this work is to investigate potential and feasibility of 60 GHz radios for very-high-data-rate short-range communications in medical applications. The measurement in a shielded room is meaningful for studying propagation characteristics in medical applications, since real surgery rooms are typically shielded. One particular usage scenario, i.e., real-time video streaming for ultrasonic imaging, was considered, where the antenna settings were adjusted to the usage scenario accordingly. Link budget and delay domain multipath characteristics were analyzed and modelled. Finally, model parameters that fit the measured power delay profiles were given.\",\"PeriodicalId\":325246,\"journal\":{\"name\":\"2010 IEEE 71st Vehicular Technology Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE 71st Vehicular Technology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/VETECS.2010.5494120\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE 71st Vehicular Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VETECS.2010.5494120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

本报告描述了在屏蔽室内进行60 GHz信道测量和建模的结果。这项工作的最终目标是研究60ghz无线电在医疗应用中用于非常高数据速率短程通信的潜力和可行性。由于真实的手术室通常是屏蔽的,因此在屏蔽室中进行测量对于研究医疗应用中的传播特性具有重要意义。考虑了一种特殊的使用场景,即用于超声成像的实时视频流,其中天线设置相应地调整到使用场景。对链路预算和延迟域多径特性进行了分析和建模。最后给出了与实测功率延迟曲线拟合的模型参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
60 GHz Radio Channel Measurements and Modeling in a Shielded Room
This report describes results from 60 GHz channel measurements and modelling in a shielded room. Final goal of this work is to investigate potential and feasibility of 60 GHz radios for very-high-data-rate short-range communications in medical applications. The measurement in a shielded room is meaningful for studying propagation characteristics in medical applications, since real surgery rooms are typically shielded. One particular usage scenario, i.e., real-time video streaming for ultrasonic imaging, was considered, where the antenna settings were adjusted to the usage scenario accordingly. Link budget and delay domain multipath characteristics were analyzed and modelled. Finally, model parameters that fit the measured power delay profiles were given.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信