电子捕获电导检测器双毛细管柱同时进样分析有机氯农药残留。

M L Hopper
{"title":"电子捕获电导检测器双毛细管柱同时进样分析有机氯农药残留。","authors":"M L Hopper","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A system has been developed that will allow low level screening of 31 organochlorine pesticide residues using simultaneous injection on 2 dissimilar capillary columns. An electron capture detector was attached to a DB-1701 column, and an electrolytic conductivity detector in the halogen mode was attached to a DB-5 column. Chlorinated pesticide amounts ranging from 0.05 ng for gamma-BHC to 1.5 ng for decamethrin can easily be quantitated and confirmed. The system can be used in either the column programmed mode or the isothermal column mode. Good reproducibility was obtained for injections in both modes. This system can easily be retrofitted to any gas chromatograph using on column or split/splitless injectors.</p>","PeriodicalId":14752,"journal":{"name":"Journal - Association of Official Analytical Chemists","volume":"74 6","pages":"974-81"},"PeriodicalIF":0.0000,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of organochlorine pesticide residues using simultaneous injection of two capillary columns with electron capture and electrolytic conductivity detectors.\",\"authors\":\"M L Hopper\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A system has been developed that will allow low level screening of 31 organochlorine pesticide residues using simultaneous injection on 2 dissimilar capillary columns. An electron capture detector was attached to a DB-1701 column, and an electrolytic conductivity detector in the halogen mode was attached to a DB-5 column. Chlorinated pesticide amounts ranging from 0.05 ng for gamma-BHC to 1.5 ng for decamethrin can easily be quantitated and confirmed. The system can be used in either the column programmed mode or the isothermal column mode. Good reproducibility was obtained for injections in both modes. This system can easily be retrofitted to any gas chromatograph using on column or split/splitless injectors.</p>\",\"PeriodicalId\":14752,\"journal\":{\"name\":\"Journal - Association of Official Analytical Chemists\",\"volume\":\"74 6\",\"pages\":\"974-81\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal - Association of Official Analytical Chemists\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal - Association of Official Analytical Chemists","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一个系统已开发,将允许低水平筛选31有机氯农药残留使用同时注射在两个不同的毛细管柱。电子捕获检测器连接在DB-1701柱上,卤素模式下的电解电导率检测器连接在DB-5柱上。氯化农药的量从γ -六六六的0.05 ng到十菊酯的1.5 ng都可以很容易地定量和确定。该系统既可用于柱程控模式,也可用于等温柱模式。在两种模式下均获得了良好的重现性。该系统可以很容易地改造到任何气相色谱仪使用柱或分裂/无分裂进样器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of organochlorine pesticide residues using simultaneous injection of two capillary columns with electron capture and electrolytic conductivity detectors.

A system has been developed that will allow low level screening of 31 organochlorine pesticide residues using simultaneous injection on 2 dissimilar capillary columns. An electron capture detector was attached to a DB-1701 column, and an electrolytic conductivity detector in the halogen mode was attached to a DB-5 column. Chlorinated pesticide amounts ranging from 0.05 ng for gamma-BHC to 1.5 ng for decamethrin can easily be quantitated and confirmed. The system can be used in either the column programmed mode or the isothermal column mode. Good reproducibility was obtained for injections in both modes. This system can easily be retrofitted to any gas chromatograph using on column or split/splitless injectors.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信