{"title":"走廊电力输送能力对称与非对称提升途径的比较研究","authors":"R. Mohamedi, S. Lefebvre, A. Ba, A. Houle","doi":"10.1109/IREP.2007.4410512","DOIUrl":null,"url":null,"abstract":"The objective of this paper is to investigate the asymmetric approach for increasing the transfer capacity of a corridor affected by single-phase faults. The paper consists of a comparative study of symmetric and asymmetric operations for a corridor with N parallel lines. The basis of the comparison is the reactive compensation required to restore the initial power flow following one or several contingencies. An economic analysis is presented for each case analyzed. The paper also aims at determining the operating conditions and criteria of analysis favorable to the asymmetric operation.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative study of the symmetric and asymmetric approaches to increase power transfer capacity of a corridor\",\"authors\":\"R. Mohamedi, S. Lefebvre, A. Ba, A. Houle\",\"doi\":\"10.1109/IREP.2007.4410512\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective of this paper is to investigate the asymmetric approach for increasing the transfer capacity of a corridor affected by single-phase faults. The paper consists of a comparative study of symmetric and asymmetric operations for a corridor with N parallel lines. The basis of the comparison is the reactive compensation required to restore the initial power flow following one or several contingencies. An economic analysis is presented for each case analyzed. The paper also aims at determining the operating conditions and criteria of analysis favorable to the asymmetric operation.\",\"PeriodicalId\":214545,\"journal\":{\"name\":\"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IREP.2007.4410512\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IREP.2007.4410512","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparative study of the symmetric and asymmetric approaches to increase power transfer capacity of a corridor
The objective of this paper is to investigate the asymmetric approach for increasing the transfer capacity of a corridor affected by single-phase faults. The paper consists of a comparative study of symmetric and asymmetric operations for a corridor with N parallel lines. The basis of the comparison is the reactive compensation required to restore the initial power flow following one or several contingencies. An economic analysis is presented for each case analyzed. The paper also aims at determining the operating conditions and criteria of analysis favorable to the asymmetric operation.