{"title":"有在役高压电缆附件PD诊断现场试验的实践经验","authors":"E. Lemke, T. Strehl, W. Weissenberg, J. Herron","doi":"10.1109/ELINSL.2006.1665365","DOIUrl":null,"url":null,"abstract":"The presented paper deals with preventive on-site PD diagnostics of HV cable terminations under operation voltage using an ultra-wide-band (UWB) PD probing. In order to assess the detected PD level quantitatively as \"equivalent apparent charge\" a sensitivity check has been performed. The results reveal that by means of the applied method potential PD defects in GIS-cable terminations could well be recognized where a PD detection sensitivity as low as few pC was achieved","PeriodicalId":427638,"journal":{"name":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Practical experiences in on-site PD diagnosis tests of HV power cable accessories in service\",\"authors\":\"E. Lemke, T. Strehl, W. Weissenberg, J. Herron\",\"doi\":\"10.1109/ELINSL.2006.1665365\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The presented paper deals with preventive on-site PD diagnostics of HV cable terminations under operation voltage using an ultra-wide-band (UWB) PD probing. In order to assess the detected PD level quantitatively as \\\"equivalent apparent charge\\\" a sensitivity check has been performed. The results reveal that by means of the applied method potential PD defects in GIS-cable terminations could well be recognized where a PD detection sensitivity as low as few pC was achieved\",\"PeriodicalId\":427638,\"journal\":{\"name\":\"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2006.1665365\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2006.1665365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Practical experiences in on-site PD diagnosis tests of HV power cable accessories in service
The presented paper deals with preventive on-site PD diagnostics of HV cable terminations under operation voltage using an ultra-wide-band (UWB) PD probing. In order to assess the detected PD level quantitatively as "equivalent apparent charge" a sensitivity check has been performed. The results reveal that by means of the applied method potential PD defects in GIS-cable terminations could well be recognized where a PD detection sensitivity as low as few pC was achieved