基于s变换和模式识别的高级串联补偿线路故障分析

P. Dash, S. Samantaray, G. Panda
{"title":"基于s变换和模式识别的高级串联补偿线路故障分析","authors":"P. Dash, S. Samantaray, G. Panda","doi":"10.1109/IPEC.2005.206956","DOIUrl":null,"url":null,"abstract":"The S-transform (ST) is an extension of wavelet transform which possesses superior property over the latter as the moving functions are fixed with respect to time axis while the localizing scalable Gaussian window dilates and translates. Phase spectrum obtained in this transform is always with respect to fixed reference point and the real and imaginary spectrum can be localized independently. Such a transform with moving and scalable localizing Gaussian window, therefore, provides excellent time localization property for different signals. Utilizing the ST fault current signal is analyzed for an advanced series compensated transmission system. The spectral analysis of the current signals at different fault conditions of the system clearly classifies the faulty phase and faulty section","PeriodicalId":164802,"journal":{"name":"2005 International Power Engineering Conference","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Fault analysis of advanced series compensated line using S-transform and pattern recognition approach\",\"authors\":\"P. Dash, S. Samantaray, G. Panda\",\"doi\":\"10.1109/IPEC.2005.206956\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The S-transform (ST) is an extension of wavelet transform which possesses superior property over the latter as the moving functions are fixed with respect to time axis while the localizing scalable Gaussian window dilates and translates. Phase spectrum obtained in this transform is always with respect to fixed reference point and the real and imaginary spectrum can be localized independently. Such a transform with moving and scalable localizing Gaussian window, therefore, provides excellent time localization property for different signals. Utilizing the ST fault current signal is analyzed for an advanced series compensated transmission system. The spectral analysis of the current signals at different fault conditions of the system clearly classifies the faulty phase and faulty section\",\"PeriodicalId\":164802,\"journal\":{\"name\":\"2005 International Power Engineering Conference\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEC.2005.206956\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEC.2005.206956","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

s变换(ST)是小波变换的一种扩展,由于运动函数相对于时间轴是固定的,而定位的可伸缩高斯窗口扩展和平移,因此具有小波变换优于小波变换的特性。该变换得到的相谱总是相对于固定的参考点,实谱和虚谱可以独立地进行局部化。因此,这种具有移动和可伸缩的定位高斯窗的变换对不同的信号提供了良好的时间定位特性。利用ST故障电流信号分析了先进的串联补偿输电系统。对系统不同故障状态下的电流信号进行频谱分析,清晰地划分出故障相位和故障截面
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault analysis of advanced series compensated line using S-transform and pattern recognition approach
The S-transform (ST) is an extension of wavelet transform which possesses superior property over the latter as the moving functions are fixed with respect to time axis while the localizing scalable Gaussian window dilates and translates. Phase spectrum obtained in this transform is always with respect to fixed reference point and the real and imaginary spectrum can be localized independently. Such a transform with moving and scalable localizing Gaussian window, therefore, provides excellent time localization property for different signals. Utilizing the ST fault current signal is analyzed for an advanced series compensated transmission system. The spectral analysis of the current signals at different fault conditions of the system clearly classifies the faulty phase and faulty section
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信