环氧涂层钢筋的设计建议

J. Cairns, J. Jirsa, S. Mccabe
{"title":"环氧涂层钢筋的设计建议","authors":"J. Cairns, J. Jirsa, S. Mccabe","doi":"10.14359/5887","DOIUrl":null,"url":null,"abstract":"Fusion bonded epoxy coated reinforcement (FBECR) has been developed to help combat problems of corrosion in reinforced concrete structures. The surface texture of the coating is smoother than the normal mill scale surface of reinforcing bars and alters bond characteristics of the bar. Although FBECR has no been in use for more than 30 years and production standards have been established, rules for design using the material are not well developed. CEB Task Group 2/5 is currently reviewing data on bond and structural performance of elements reinforced with FBECR with the aim of deriving recommendations for design practice which will enable structures reinforced with FBECR to achieve equivalent performance to that f structures reinforced with millscale surface ribbed bars. This paper presents proposals for amendments to the CEB-FIP model Code 1990 for design of anchorages and splices of coated bars, and briefly reviews other aspects of structural performance influenced by the different bond characteristics of FBECR.","PeriodicalId":273104,"journal":{"name":"SP-180: Bond and Development of Reinforcement - A Tribute to Dr. Peter Gergely","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design Recommendations for Epoxy-Coated Reinforcement\",\"authors\":\"J. Cairns, J. Jirsa, S. Mccabe\",\"doi\":\"10.14359/5887\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Fusion bonded epoxy coated reinforcement (FBECR) has been developed to help combat problems of corrosion in reinforced concrete structures. The surface texture of the coating is smoother than the normal mill scale surface of reinforcing bars and alters bond characteristics of the bar. Although FBECR has no been in use for more than 30 years and production standards have been established, rules for design using the material are not well developed. CEB Task Group 2/5 is currently reviewing data on bond and structural performance of elements reinforced with FBECR with the aim of deriving recommendations for design practice which will enable structures reinforced with FBECR to achieve equivalent performance to that f structures reinforced with millscale surface ribbed bars. This paper presents proposals for amendments to the CEB-FIP model Code 1990 for design of anchorages and splices of coated bars, and briefly reviews other aspects of structural performance influenced by the different bond characteristics of FBECR.\",\"PeriodicalId\":273104,\"journal\":{\"name\":\"SP-180: Bond and Development of Reinforcement - A Tribute to Dr. Peter Gergely\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SP-180: Bond and Development of Reinforcement - A Tribute to Dr. Peter Gergely\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14359/5887\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-180: Bond and Development of Reinforcement - A Tribute to Dr. Peter Gergely","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/5887","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

熔合环氧涂层钢筋(FBECR)的发展有助于解决钢筋混凝土结构中的腐蚀问题。涂层的表面纹理比普通钢筋的磨皮表面光滑,改变了钢筋的结合特性。尽管FBECR已经使用了30多年,并且已经建立了生产标准,但使用该材料的设计规则并没有得到很好的发展。CEB第2/5任务组目前正在审查用FBECR加固的构件的粘结和结构性能数据,目的是为设计实践提出建议,使用FBECR加固的结构达到与用微米级表面肋筋加固的结构相当的性能。本文提出了对CEB-FIP模型规范1990中关于涂覆钢筋锚固和接头设计的修改建议,并简要回顾了受FBECR不同粘结特性影响的结构性能的其他方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design Recommendations for Epoxy-Coated Reinforcement
Fusion bonded epoxy coated reinforcement (FBECR) has been developed to help combat problems of corrosion in reinforced concrete structures. The surface texture of the coating is smoother than the normal mill scale surface of reinforcing bars and alters bond characteristics of the bar. Although FBECR has no been in use for more than 30 years and production standards have been established, rules for design using the material are not well developed. CEB Task Group 2/5 is currently reviewing data on bond and structural performance of elements reinforced with FBECR with the aim of deriving recommendations for design practice which will enable structures reinforced with FBECR to achieve equivalent performance to that f structures reinforced with millscale surface ribbed bars. This paper presents proposals for amendments to the CEB-FIP model Code 1990 for design of anchorages and splices of coated bars, and briefly reviews other aspects of structural performance influenced by the different bond characteristics of FBECR.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信