聚合物可生物降解固定物在治疗关节内骨折中的应用

Aleksej M Fajn, A. Vaza, E. Mamatov, E. A. Zhirkova, Sergej F Gneteckij, R. Titov, K. I. Skuratovskaya
{"title":"聚合物可生物降解固定物在治疗关节内骨折中的应用","authors":"Aleksej M Fajn, A. Vaza, E. Mamatov, E. A. Zhirkova, Sergej F Gneteckij, R. Titov, K. I. Skuratovskaya","doi":"10.53652/2782-1730-2022-3-1-15-25","DOIUrl":null,"url":null,"abstract":"We have observed an increase in the number of patients with intra-articular fractures, as well as in the severity of such fractures. Traditionally, metal implants such as wires, capless screws, Herbert screws are used for osteosynthesis of intra-articular fractures with small bone and cartilage fragments. However, the metal implants have their drawbacks. Biodegradable fixatives (BDF) made from a copolymer of polylactic and polyglycolic acids (PLGA) could be an alternative to the implants. Two groups of 132 people with intra-articular fractures of different localization were formed, biodegradable implants were used in the main group, metal implants were used in the control group. The groups were correlated by sex, age and nature of fractures. We compared the time spent in the operating room for similar operations, the number of operations to remove the fixators in both groups, and the number of complications. Compared functional outcomes. We assessed the possibility of interpreting MSCT and MRI data in the isolated use of BDF. In the group with the use of biodegradable implants, fewer removal operations were required (44%) than in the group without the use of biodegradable implants (58%), which is statistically significant. Complications developed in the main group amounted to 3% (4 cases), while in the group with metal implants they amounted to 10% (13 cases). We have found that the use of biodegradable implants has satisfactory clinical results, a low percentage of implant removal operations, and lower complications rate.","PeriodicalId":344630,"journal":{"name":"Medical Bulletin of the Main Military Clinical Hospital named after N.N. Burdenko","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Polymer biodegradable fixators in the treatment of near- and intra articular fractures\",\"authors\":\"Aleksej M Fajn, A. Vaza, E. Mamatov, E. A. Zhirkova, Sergej F Gneteckij, R. Titov, K. I. Skuratovskaya\",\"doi\":\"10.53652/2782-1730-2022-3-1-15-25\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have observed an increase in the number of patients with intra-articular fractures, as well as in the severity of such fractures. Traditionally, metal implants such as wires, capless screws, Herbert screws are used for osteosynthesis of intra-articular fractures with small bone and cartilage fragments. However, the metal implants have their drawbacks. Biodegradable fixatives (BDF) made from a copolymer of polylactic and polyglycolic acids (PLGA) could be an alternative to the implants. Two groups of 132 people with intra-articular fractures of different localization were formed, biodegradable implants were used in the main group, metal implants were used in the control group. The groups were correlated by sex, age and nature of fractures. We compared the time spent in the operating room for similar operations, the number of operations to remove the fixators in both groups, and the number of complications. Compared functional outcomes. We assessed the possibility of interpreting MSCT and MRI data in the isolated use of BDF. In the group with the use of biodegradable implants, fewer removal operations were required (44%) than in the group without the use of biodegradable implants (58%), which is statistically significant. Complications developed in the main group amounted to 3% (4 cases), while in the group with metal implants they amounted to 10% (13 cases). We have found that the use of biodegradable implants has satisfactory clinical results, a low percentage of implant removal operations, and lower complications rate.\",\"PeriodicalId\":344630,\"journal\":{\"name\":\"Medical Bulletin of the Main Military Clinical Hospital named after N.N. Burdenko\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Bulletin of the Main Military Clinical Hospital named after N.N. Burdenko\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53652/2782-1730-2022-3-1-15-25\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Bulletin of the Main Military Clinical Hospital named after N.N. Burdenko","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53652/2782-1730-2022-3-1-15-25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们观察到关节内骨折患者数量的增加,以及这种骨折的严重程度。传统上,金属植入物如金属丝、无帽螺钉、赫伯特螺钉用于小骨和软骨碎片的关节内骨折的骨融合术。然而,金属植入物也有其缺点。由聚乳酸和聚乙醇酸(PLGA)共聚物制成的可生物降解固定剂(BDF)可以作为植入物的替代品。将132例不同定位的关节内骨折患者分为两组,主组采用生物可降解假体,对照组采用金属假体。这些组是根据性别、年龄和骨折的性质来关联的。我们比较了两组患者在手术室进行类似手术的时间、拆除固定架的手术次数以及并发症的数量。比较功能结果。我们评估了单独使用BDF解释MSCT和MRI数据的可能性。在使用生物可降解种植体的组中,所需的移除手术(44%)少于未使用生物可降解种植体的组(58%),这在统计学上具有显著性。主组并发症发生率为3%(4例),金属种植体组并发症发生率为10%(13例)。我们发现使用生物可降解种植体具有令人满意的临床效果,种植体移除手术比例低,并发症发生率低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Polymer biodegradable fixators in the treatment of near- and intra articular fractures
We have observed an increase in the number of patients with intra-articular fractures, as well as in the severity of such fractures. Traditionally, metal implants such as wires, capless screws, Herbert screws are used for osteosynthesis of intra-articular fractures with small bone and cartilage fragments. However, the metal implants have their drawbacks. Biodegradable fixatives (BDF) made from a copolymer of polylactic and polyglycolic acids (PLGA) could be an alternative to the implants. Two groups of 132 people with intra-articular fractures of different localization were formed, biodegradable implants were used in the main group, metal implants were used in the control group. The groups were correlated by sex, age and nature of fractures. We compared the time spent in the operating room for similar operations, the number of operations to remove the fixators in both groups, and the number of complications. Compared functional outcomes. We assessed the possibility of interpreting MSCT and MRI data in the isolated use of BDF. In the group with the use of biodegradable implants, fewer removal operations were required (44%) than in the group without the use of biodegradable implants (58%), which is statistically significant. Complications developed in the main group amounted to 3% (4 cases), while in the group with metal implants they amounted to 10% (13 cases). We have found that the use of biodegradable implants has satisfactory clinical results, a low percentage of implant removal operations, and lower complications rate.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信