{"title":"MESA P2实验用双散射偏振计","authors":"M. Molitor, K. Aulenbacher","doi":"10.22323/1.243.0030","DOIUrl":null,"url":null,"abstract":"The P2 Experiment at the new Mainz Energy-recovering Superconducting Accelerator (MESA) aims at measuring the weak mixing angle $\\sin^2 \\theta_\\text{W}$ at low Q$^2$ with high precision. Therefore the polarization of the incident electron beam has to be known with a very high accuracy (< 0.5 %). A conventional Mott-polarimeter requires a lot of effort in calibration to be able to acieve this goal. \n \nA Double Scattering Polarimeter (DSP) promises to meet these requirements with less effort.","PeriodicalId":166894,"journal":{"name":"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Double scattering polarimeter for the P2 experiment at MESA\",\"authors\":\"M. Molitor, K. Aulenbacher\",\"doi\":\"10.22323/1.243.0030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The P2 Experiment at the new Mainz Energy-recovering Superconducting Accelerator (MESA) aims at measuring the weak mixing angle $\\\\sin^2 \\\\theta_\\\\text{W}$ at low Q$^2$ with high precision. Therefore the polarization of the incident electron beam has to be known with a very high accuracy (< 0.5 %). A conventional Mott-polarimeter requires a lot of effort in calibration to be able to acieve this goal. \\n \\nA Double Scattering Polarimeter (DSP) promises to meet these requirements with less effort.\",\"PeriodicalId\":166894,\"journal\":{\"name\":\"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22323/1.243.0030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of XVII International Workshop on Polarized Sources, Targets & Polarimetry — PoS(PSTP2017)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22323/1.243.0030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在新的美因茨能量回收超导加速器(MESA)上进行的P2实验旨在高精度地测量低Q $^2$下的弱混合角$\sin^2 \theta_\text{W}$。因此,入射电子束的极化必须以非常高的精度(< 0.5 %). A conventional Mott-polarimeter requires a lot of effort in calibration to be able to acieve this goal. A Double Scattering Polarimeter (DSP) promises to meet these requirements with less effort.
A Double scattering polarimeter for the P2 experiment at MESA
The P2 Experiment at the new Mainz Energy-recovering Superconducting Accelerator (MESA) aims at measuring the weak mixing angle $\sin^2 \theta_\text{W}$ at low Q$^2$ with high precision. Therefore the polarization of the incident electron beam has to be known with a very high accuracy (< 0.5 %). A conventional Mott-polarimeter requires a lot of effort in calibration to be able to acieve this goal.
A Double Scattering Polarimeter (DSP) promises to meet these requirements with less effort.