氧化物可靠性:参数测试可靠性评估的新方法

R. Bottini, A. Sebastiani, N. Galbiati, C. Scozzari, G. Ghidini
{"title":"氧化物可靠性:参数测试可靠性评估的新方法","authors":"R. Bottini, A. Sebastiani, N. Galbiati, C. Scozzari, G. Ghidini","doi":"10.1109/IRWS.2006.305230","DOIUrl":null,"url":null,"abstract":"Aim of this work is to propose a new fast methodology to be applied to thick gate and tunnel oxides in Flash and embedded Flash processes. Starting from the reliability characterization of the dielectric it is possible to define a very short stress (lower than 1-2sec) which correlates with standard long reliability testing procedures (constant voltage stress, CVS, or constant current stress, CCS). For thick dielectrics, whose significant charge trapping affects the lifetime, the definition of a short stress condition is critical, but it is shown that a short CCS test can overcome this problem. This short test can be introduced at parametric testing in order to screen defective oxides following a criteria directly correlated with device requirements","PeriodicalId":199223,"journal":{"name":"2006 IEEE International Integrated Reliability Workshop Final Report","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Oxide Reliability: a new Methodology for Reliability Evaluation at Parametric Testing\",\"authors\":\"R. Bottini, A. Sebastiani, N. Galbiati, C. Scozzari, G. Ghidini\",\"doi\":\"10.1109/IRWS.2006.305230\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim of this work is to propose a new fast methodology to be applied to thick gate and tunnel oxides in Flash and embedded Flash processes. Starting from the reliability characterization of the dielectric it is possible to define a very short stress (lower than 1-2sec) which correlates with standard long reliability testing procedures (constant voltage stress, CVS, or constant current stress, CCS). For thick dielectrics, whose significant charge trapping affects the lifetime, the definition of a short stress condition is critical, but it is shown that a short CCS test can overcome this problem. This short test can be introduced at parametric testing in order to screen defective oxides following a criteria directly correlated with device requirements\",\"PeriodicalId\":199223,\"journal\":{\"name\":\"2006 IEEE International Integrated Reliability Workshop Final Report\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE International Integrated Reliability Workshop Final Report\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IRWS.2006.305230\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Integrated Reliability Workshop Final Report","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRWS.2006.305230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本工作的目的是提出一种新的快速方法,应用于Flash和嵌入式Flash工艺中的厚栅和隧道氧化物。从电介质的可靠性特性开始,可以定义一个非常短的应力(低于1-2sec),这与标准的长时间可靠性测试程序(恒压应力,CVS或恒流应力,CCS)相关。对于厚介质,其显著的电荷捕获影响寿命,短应力条件的定义是至关重要的,但表明,一个短的CCS测试可以克服这一问题。这个简短的测试可以在参数测试中引入,以便根据与设备要求直接相关的标准筛选有缺陷的氧化物
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Oxide Reliability: a new Methodology for Reliability Evaluation at Parametric Testing
Aim of this work is to propose a new fast methodology to be applied to thick gate and tunnel oxides in Flash and embedded Flash processes. Starting from the reliability characterization of the dielectric it is possible to define a very short stress (lower than 1-2sec) which correlates with standard long reliability testing procedures (constant voltage stress, CVS, or constant current stress, CCS). For thick dielectrics, whose significant charge trapping affects the lifetime, the definition of a short stress condition is critical, but it is shown that a short CCS test can overcome this problem. This short test can be introduced at parametric testing in order to screen defective oxides following a criteria directly correlated with device requirements
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信