高压导体热性能的检验

D. Szabó, M. Kovács, B. Németh, M. Bizjak
{"title":"高压导体热性能的检验","authors":"D. Szabó, M. Kovács, B. Németh, M. Bizjak","doi":"10.1109/IYCE45807.2019.8991590","DOIUrl":null,"url":null,"abstract":"Due to the increasing energy demand, new questions raise for engineers such as how to achieve high utilization of the existing transmission system. For this purpose, the investigation of network equipment and elements is indispensable. Dynamic line rating (DLR) is a cost-efficient way to raise the transmission power capacity of the existing high voltage overhead lines. DLR technology is based on the real-time thermal equilibrium of the conductors, which is the basis of the ampacity calculation of the given line. Therefore, the investigation of the thermal behavior of wires is essential to fine tune the existing calculation methodologies. The aim of this paper is to present the research regarding to the thermal behavior of high voltage conductors performed in the High Voltage Laboratory of Budapest University of Technology and Economics. In this research the time constant of a wire was determined both in case of different static and dynamic thermal processes, thus the heating and cooling mechanism of the conductor can be described in a more precise way in case of thermal monitoring of the wires.","PeriodicalId":226881,"journal":{"name":"2019 7th International Youth Conference on Energy (IYCE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Examination of thermal behavior of high voltage conductors\",\"authors\":\"D. Szabó, M. Kovács, B. Németh, M. Bizjak\",\"doi\":\"10.1109/IYCE45807.2019.8991590\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to the increasing energy demand, new questions raise for engineers such as how to achieve high utilization of the existing transmission system. For this purpose, the investigation of network equipment and elements is indispensable. Dynamic line rating (DLR) is a cost-efficient way to raise the transmission power capacity of the existing high voltage overhead lines. DLR technology is based on the real-time thermal equilibrium of the conductors, which is the basis of the ampacity calculation of the given line. Therefore, the investigation of the thermal behavior of wires is essential to fine tune the existing calculation methodologies. The aim of this paper is to present the research regarding to the thermal behavior of high voltage conductors performed in the High Voltage Laboratory of Budapest University of Technology and Economics. In this research the time constant of a wire was determined both in case of different static and dynamic thermal processes, thus the heating and cooling mechanism of the conductor can be described in a more precise way in case of thermal monitoring of the wires.\",\"PeriodicalId\":226881,\"journal\":{\"name\":\"2019 7th International Youth Conference on Energy (IYCE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 7th International Youth Conference on Energy (IYCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IYCE45807.2019.8991590\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 7th International Youth Conference on Energy (IYCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IYCE45807.2019.8991590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

随着能源需求的不断增加,如何实现现有输电系统的高效利用等新问题也给工程师们提出了新的问题。为此,对网络设备和要素的调查是必不可少的。动态线路额定值(DLR)是提高现有高压架空线输电容量的一种经济有效的方法。DLR技术是基于导线的实时热平衡,这是给定线路的电流计算的基础。因此,电线的热行为的研究是必要的微调现有的计算方法。本文的目的是介绍在布达佩斯科技与经济大学高压实验室进行的关于高压导体热行为的研究。在本研究中,确定了导线在不同静态和动态热过程下的时间常数,从而在对导线进行热监测时可以更精确地描述导线的加热和冷却机理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Examination of thermal behavior of high voltage conductors
Due to the increasing energy demand, new questions raise for engineers such as how to achieve high utilization of the existing transmission system. For this purpose, the investigation of network equipment and elements is indispensable. Dynamic line rating (DLR) is a cost-efficient way to raise the transmission power capacity of the existing high voltage overhead lines. DLR technology is based on the real-time thermal equilibrium of the conductors, which is the basis of the ampacity calculation of the given line. Therefore, the investigation of the thermal behavior of wires is essential to fine tune the existing calculation methodologies. The aim of this paper is to present the research regarding to the thermal behavior of high voltage conductors performed in the High Voltage Laboratory of Budapest University of Technology and Economics. In this research the time constant of a wire was determined both in case of different static and dynamic thermal processes, thus the heating and cooling mechanism of the conductor can be described in a more precise way in case of thermal monitoring of the wires.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信