J. Cheon, Choon-Kyoug Kim, Jongmoo Lee, Soonman Kwon
{"title":"控制棒控制系统中功率转换模块故障检测的新方法","authors":"J. Cheon, Choon-Kyoug Kim, Jongmoo Lee, Soonman Kwon","doi":"10.1109/ISIE.2006.295705","DOIUrl":null,"url":null,"abstract":"In this paper, we introduce a new method for detecting failures of a power converter module in control rod control system of a nuclear power plant. The failure called the phase failure and occurring in a power converter module can exert harmful influence upon the operation of the associated control rod drive mechanism for driving neutron-absorbing control rods controlling the thermal output of the reactor. Because of this adverse condition, it is necessary that the phase failure should be detected quickly and correctly. We devised a new method for detecting the phase failure for the digital power controller and solved the drawbacks of the existing failure detector","PeriodicalId":296467,"journal":{"name":"2006 IEEE International Symposium on Industrial Electronics","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"New Method for Detecting Failures of Power Converter Module in Control Rod Control System\",\"authors\":\"J. Cheon, Choon-Kyoug Kim, Jongmoo Lee, Soonman Kwon\",\"doi\":\"10.1109/ISIE.2006.295705\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we introduce a new method for detecting failures of a power converter module in control rod control system of a nuclear power plant. The failure called the phase failure and occurring in a power converter module can exert harmful influence upon the operation of the associated control rod drive mechanism for driving neutron-absorbing control rods controlling the thermal output of the reactor. Because of this adverse condition, it is necessary that the phase failure should be detected quickly and correctly. We devised a new method for detecting the phase failure for the digital power controller and solved the drawbacks of the existing failure detector\",\"PeriodicalId\":296467,\"journal\":{\"name\":\"2006 IEEE International Symposium on Industrial Electronics\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-07-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE International Symposium on Industrial Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2006.295705\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2006.295705","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
New Method for Detecting Failures of Power Converter Module in Control Rod Control System
In this paper, we introduce a new method for detecting failures of a power converter module in control rod control system of a nuclear power plant. The failure called the phase failure and occurring in a power converter module can exert harmful influence upon the operation of the associated control rod drive mechanism for driving neutron-absorbing control rods controlling the thermal output of the reactor. Because of this adverse condition, it is necessary that the phase failure should be detected quickly and correctly. We devised a new method for detecting the phase failure for the digital power controller and solved the drawbacks of the existing failure detector