打桩引起的地基振动分析及振动预测方法的比较

J. Cleary, E. Steward
{"title":"打桩引起的地基振动分析及振动预测方法的比较","authors":"J. Cleary, E. Steward","doi":"10.1080/19375247.2017.1288855","DOIUrl":null,"url":null,"abstract":"A project was conducted to collect ground vibration data while driving three piles, one square concrete pile and two steel H-piles, in Mobile, AL. The vibration data were analysed in several ways to quantify the vibration magnitudes including using the horizontal distance, the scaled-distance approach and the seismic distance (SD). For each analysis, two prediction equations were fit to the data, one for the concrete pile and one for the H-piles. In each case, the soil attenuation parameter was larger for the concrete pile (1.6 for horizontal and scaled-distance, and 2.11 for SD) than the H-piles (0.93 for horizontal and scaled-distance, and 1.01 for SD). An example design is presented to outline the use of each method and compare the results. The example provides practitioners with a guideline to follow when evaluating which analysis procedures to consider for a specific project.","PeriodicalId":272645,"journal":{"name":"DFI Journal - The Journal of the Deep Foundations Institute","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Analysis of ground vibrations induced by pile driving and a comparison of vibration prediction methods\",\"authors\":\"J. Cleary, E. Steward\",\"doi\":\"10.1080/19375247.2017.1288855\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A project was conducted to collect ground vibration data while driving three piles, one square concrete pile and two steel H-piles, in Mobile, AL. The vibration data were analysed in several ways to quantify the vibration magnitudes including using the horizontal distance, the scaled-distance approach and the seismic distance (SD). For each analysis, two prediction equations were fit to the data, one for the concrete pile and one for the H-piles. In each case, the soil attenuation parameter was larger for the concrete pile (1.6 for horizontal and scaled-distance, and 2.11 for SD) than the H-piles (0.93 for horizontal and scaled-distance, and 1.01 for SD). An example design is presented to outline the use of each method and compare the results. The example provides practitioners with a guideline to follow when evaluating which analysis procedures to consider for a specific project.\",\"PeriodicalId\":272645,\"journal\":{\"name\":\"DFI Journal - The Journal of the Deep Foundations Institute\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DFI Journal - The Journal of the Deep Foundations Institute\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/19375247.2017.1288855\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DFI Journal - The Journal of the Deep Foundations Institute","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/19375247.2017.1288855","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

在AL Mobile,进行了一个项目,收集了三个桩,一个方形混凝土桩和两个h型钢桩的地面振动数据。振动数据通过几种方法进行分析,包括使用水平距离,比例距离方法和地震距离(SD)来量化振动大小。对于每次分析,两个预测方程适合于数据,一个用于混凝土桩,一个用于h型桩。在两种情况下,混凝土桩的土壤衰减参数(水平和标距为1.6,SD为2.11)均大于h型桩(水平和标距为0.93,SD为1.01)。给出了一个实例设计,概述了每种方法的使用并比较了结果。这个例子为实践者提供了一个指导方针,在评估为特定项目考虑哪些分析过程时可以遵循。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of ground vibrations induced by pile driving and a comparison of vibration prediction methods
A project was conducted to collect ground vibration data while driving three piles, one square concrete pile and two steel H-piles, in Mobile, AL. The vibration data were analysed in several ways to quantify the vibration magnitudes including using the horizontal distance, the scaled-distance approach and the seismic distance (SD). For each analysis, two prediction equations were fit to the data, one for the concrete pile and one for the H-piles. In each case, the soil attenuation parameter was larger for the concrete pile (1.6 for horizontal and scaled-distance, and 2.11 for SD) than the H-piles (0.93 for horizontal and scaled-distance, and 1.01 for SD). An example design is presented to outline the use of each method and compare the results. The example provides practitioners with a guideline to follow when evaluating which analysis procedures to consider for a specific project.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信