{"title":"基于AVC系统的在线电压稳定监测系统","authors":"Xiaoqun Ding, Ling Zhou, Li Hongliang","doi":"10.1109/UPEC.2008.4651446","DOIUrl":null,"url":null,"abstract":"This paper presents that when power/voltage automatic control system (AVC) is being applied in provincial dispatching centre, in order to implement reactive power/voltage optimization control on condition of ensuring limited on-line voltage stability margin, monitoring module of on-line voltage stability should be introduced to realize the coordinated closed loop control of on-line voltage stability monitoring and AVC system. It defines the concepts of voltage lower limit of on-line voltage stability constraint and dynamic reactive power reserves of generator and considered them for AVC system as constraints to enhance the reliability and security of AVC system. The successful application in Fujian power grid indicate that the proposed method can reduce system active power loss based on ensuring limited on-line voltage stability margin.","PeriodicalId":287461,"journal":{"name":"2008 43rd International Universities Power Engineering Conference","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"AVC system based on on-line voltage stability monitoring system\",\"authors\":\"Xiaoqun Ding, Ling Zhou, Li Hongliang\",\"doi\":\"10.1109/UPEC.2008.4651446\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents that when power/voltage automatic control system (AVC) is being applied in provincial dispatching centre, in order to implement reactive power/voltage optimization control on condition of ensuring limited on-line voltage stability margin, monitoring module of on-line voltage stability should be introduced to realize the coordinated closed loop control of on-line voltage stability monitoring and AVC system. It defines the concepts of voltage lower limit of on-line voltage stability constraint and dynamic reactive power reserves of generator and considered them for AVC system as constraints to enhance the reliability and security of AVC system. The successful application in Fujian power grid indicate that the proposed method can reduce system active power loss based on ensuring limited on-line voltage stability margin.\",\"PeriodicalId\":287461,\"journal\":{\"name\":\"2008 43rd International Universities Power Engineering Conference\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 43rd International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2008.4651446\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 43rd International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2008.4651446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
AVC system based on on-line voltage stability monitoring system
This paper presents that when power/voltage automatic control system (AVC) is being applied in provincial dispatching centre, in order to implement reactive power/voltage optimization control on condition of ensuring limited on-line voltage stability margin, monitoring module of on-line voltage stability should be introduced to realize the coordinated closed loop control of on-line voltage stability monitoring and AVC system. It defines the concepts of voltage lower limit of on-line voltage stability constraint and dynamic reactive power reserves of generator and considered them for AVC system as constraints to enhance the reliability and security of AVC system. The successful application in Fujian power grid indicate that the proposed method can reduce system active power loss based on ensuring limited on-line voltage stability margin.