压实对电阻率值的影响

Ahmad Khairul Abd Malik, Amirul Haziq Hazam Rizal, A. Madun
{"title":"压实对电阻率值的影响","authors":"Ahmad Khairul Abd Malik, Amirul Haziq Hazam Rizal, A. Madun","doi":"10.30880/jsue.2022.02.01.004","DOIUrl":null,"url":null,"abstract":"Electrical resistivity tomography is a non-destructive method of site investigation that involvesinjecting electricity into the sample and measuring subsurface resistance. This study looked at the effects of compaction on resistivity values as well as the relationship between different degrees of compaction. The material used in this experiment was laterite soil. The sample was tested into a standard proctor mould. The model has 10.20cm diameter and 11.6 cm for height of the mould. Each sample's resistivity was measured entirely compacted.The resistivity testing in this study were conducted using the Miller 400A. ASTM D 422 Standards were used, and for electrical resistivity testing, ASTM G57 is used. This research emphasises the impact of moisture content on resistivity value, as soil reduces resistivity value when the soil has higher moisture content which is 120 Ωm at 37%, and 190 Ωm at 25%. By comparing the results of different moisture content of soil samples under varied degrees of compaction, better resistivity interpretation tables may be generated.","PeriodicalId":277750,"journal":{"name":"Journal of Sustainable Underground Exploration","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Compaction Towards Resistivity Value\",\"authors\":\"Ahmad Khairul Abd Malik, Amirul Haziq Hazam Rizal, A. Madun\",\"doi\":\"10.30880/jsue.2022.02.01.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrical resistivity tomography is a non-destructive method of site investigation that involvesinjecting electricity into the sample and measuring subsurface resistance. This study looked at the effects of compaction on resistivity values as well as the relationship between different degrees of compaction. The material used in this experiment was laterite soil. The sample was tested into a standard proctor mould. The model has 10.20cm diameter and 11.6 cm for height of the mould. Each sample's resistivity was measured entirely compacted.The resistivity testing in this study were conducted using the Miller 400A. ASTM D 422 Standards were used, and for electrical resistivity testing, ASTM G57 is used. This research emphasises the impact of moisture content on resistivity value, as soil reduces resistivity value when the soil has higher moisture content which is 120 Ωm at 37%, and 190 Ωm at 25%. By comparing the results of different moisture content of soil samples under varied degrees of compaction, better resistivity interpretation tables may be generated.\",\"PeriodicalId\":277750,\"journal\":{\"name\":\"Journal of Sustainable Underground Exploration\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Sustainable Underground Exploration\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30880/jsue.2022.02.01.004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sustainable Underground Exploration","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30880/jsue.2022.02.01.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电阻率层析成像是一种非破坏性的现场调查方法,包括向样品中注入电并测量地下电阻。本研究考察了压实对电阻率值的影响以及不同压实程度之间的关系。本实验所用材料为红土。样品在标准普罗克特模具中进行了测试。模型直径10.20厘米,模具高度11.6厘米。每个样品的电阻率测量完全压实。本研究的电阻率测试采用Miller 400A进行。采用ASTM D 422标准,电阻率测试采用ASTM G57标准。本研究强调含水率对电阻率值的影响,土壤含水率较高时电阻率值降低,含水率为120 Ωm(37%),含水率为190 Ωm(25%)。通过比较不同压实程度下土样不同含水率的结果,可以得到更好的电阻率解释表。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Compaction Towards Resistivity Value
Electrical resistivity tomography is a non-destructive method of site investigation that involvesinjecting electricity into the sample and measuring subsurface resistance. This study looked at the effects of compaction on resistivity values as well as the relationship between different degrees of compaction. The material used in this experiment was laterite soil. The sample was tested into a standard proctor mould. The model has 10.20cm diameter and 11.6 cm for height of the mould. Each sample's resistivity was measured entirely compacted.The resistivity testing in this study were conducted using the Miller 400A. ASTM D 422 Standards were used, and for electrical resistivity testing, ASTM G57 is used. This research emphasises the impact of moisture content on resistivity value, as soil reduces resistivity value when the soil has higher moisture content which is 120 Ωm at 37%, and 190 Ωm at 25%. By comparing the results of different moisture content of soil samples under varied degrees of compaction, better resistivity interpretation tables may be generated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信