使用ECG表面电极测量早产儿呼吸速率

H. Kuo, Ning-Huei Peng, T. Kao, Weichih Hu
{"title":"使用ECG表面电极测量早产儿呼吸速率","authors":"H. Kuo, Ning-Huei Peng, T. Kao, Weichih Hu","doi":"10.1109/ISBB.2014.6820926","DOIUrl":null,"url":null,"abstract":"Sudden infant death syndrome (SIDS) is the common cause of death in infants. Apnea is known to be associated with increased incidence of the SIDS. A cessation of breathing, longer than 15 seconds, or accompanied by hypoxia or bradycardia, is called apnea of prematurity and has been found in more than 50% of premature infants. We have designed and constructed an apnea detector for infant monitoring in a clinical environment. The device uses a breath processor module with a surface ECG for detecting apnea. When the infant's breathing counts and heart rates are abnormal, an alarm will sound. This device has shown good performance and feasibility.","PeriodicalId":265886,"journal":{"name":"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Using ECG surface electrodes in measurement of respiration rate for preterm infants\",\"authors\":\"H. Kuo, Ning-Huei Peng, T. Kao, Weichih Hu\",\"doi\":\"10.1109/ISBB.2014.6820926\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sudden infant death syndrome (SIDS) is the common cause of death in infants. Apnea is known to be associated with increased incidence of the SIDS. A cessation of breathing, longer than 15 seconds, or accompanied by hypoxia or bradycardia, is called apnea of prematurity and has been found in more than 50% of premature infants. We have designed and constructed an apnea detector for infant monitoring in a clinical environment. The device uses a breath processor module with a surface ECG for detecting apnea. When the infant's breathing counts and heart rates are abnormal, an alarm will sound. This device has shown good performance and feasibility.\",\"PeriodicalId\":265886,\"journal\":{\"name\":\"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBB.2014.6820926\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBB.2014.6820926","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

婴儿猝死综合症(SIDS)是婴儿死亡的常见原因。众所周知,呼吸暂停与小岛屿发展中国家发病率增加有关。呼吸停止超过15秒,或伴有缺氧或心动过缓,被称为早产呼吸暂停,超过50%的早产儿都有这种情况。我们设计并制造了一种用于临床环境中婴儿监测的呼吸暂停检测器。该设备使用带有表面ECG的呼吸处理器模块来检测呼吸暂停。当婴儿的呼吸计数和心率异常时,警报就会响起。该装置具有良好的性能和可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Using ECG surface electrodes in measurement of respiration rate for preterm infants
Sudden infant death syndrome (SIDS) is the common cause of death in infants. Apnea is known to be associated with increased incidence of the SIDS. A cessation of breathing, longer than 15 seconds, or accompanied by hypoxia or bradycardia, is called apnea of prematurity and has been found in more than 50% of premature infants. We have designed and constructed an apnea detector for infant monitoring in a clinical environment. The device uses a breath processor module with a surface ECG for detecting apnea. When the infant's breathing counts and heart rates are abnormal, an alarm will sound. This device has shown good performance and feasibility.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信