{"title":"THOR 50M假人与HYBRID III 50假人头部标定的差异研究","authors":"Zhixin Liu, Wei-Dong Liu, Weijie Ma, Bingxu Duan","doi":"10.1109/ICSCDE54196.2021.00071","DOIUrl":null,"url":null,"abstract":"In order to explore the difference between the head calibration of the THOR 50M dummy and the HYBRID III 50th dummy, the head structure of the two dummies are compared and analyzed, and then the calibration methods are compared, and the calibration performance indexes of the two dummies are compared. The results show that the head structure of the THOR 50M dummy is more complex than that of the HYBRID III 50th dummy, The head part of the THOR 50M dummy is three times that of the Hybrid III 50 dummy; The head calibration of the THOR 50M dummy consists of two parts, the forehead and the face, while the HYBRID III 50th dummy consists of only one part of the head. In the aspect of calibration performance index, the head calibration limits of the THOR 50M dummy and the HYBRID III 50th dummy are different, and the number of calibration indexes is also different. The calibration indexes of the THOR 50M dummy are more comprehensive.","PeriodicalId":208108,"journal":{"name":"2021 International Conference of Social Computing and Digital Economy (ICSCDE)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on the difference of head calibration between the THOR 50M dummy and HYBRID III 50th dummy\",\"authors\":\"Zhixin Liu, Wei-Dong Liu, Weijie Ma, Bingxu Duan\",\"doi\":\"10.1109/ICSCDE54196.2021.00071\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to explore the difference between the head calibration of the THOR 50M dummy and the HYBRID III 50th dummy, the head structure of the two dummies are compared and analyzed, and then the calibration methods are compared, and the calibration performance indexes of the two dummies are compared. The results show that the head structure of the THOR 50M dummy is more complex than that of the HYBRID III 50th dummy, The head part of the THOR 50M dummy is three times that of the Hybrid III 50 dummy; The head calibration of the THOR 50M dummy consists of two parts, the forehead and the face, while the HYBRID III 50th dummy consists of only one part of the head. In the aspect of calibration performance index, the head calibration limits of the THOR 50M dummy and the HYBRID III 50th dummy are different, and the number of calibration indexes is also different. The calibration indexes of the THOR 50M dummy are more comprehensive.\",\"PeriodicalId\":208108,\"journal\":{\"name\":\"2021 International Conference of Social Computing and Digital Economy (ICSCDE)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference of Social Computing and Digital Economy (ICSCDE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSCDE54196.2021.00071\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference of Social Computing and Digital Economy (ICSCDE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSCDE54196.2021.00071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
为了探讨THOR 50M假人与HYBRID III 50假人头部标定的差异,对两种假人的头部结构进行了比较分析,然后对标定方法进行了比较,并对两种假人的标定性能指标进行了比较。结果表明:THOR 50M假人的头部结构比HYBRID III 50假人复杂,其头部部分是HYBRID III 50假人的3倍;THOR 50M假人的头部校准由前额和面部两部分组成,而HYBRID III 50假人仅由头部的一部分组成。在标定性能指标方面,THOR 50M假人与HYBRID III 50假人的头部标定限值不同,标定指标的数量也不同。THOR 50M假人的标定指标更为全面。
Research on the difference of head calibration between the THOR 50M dummy and HYBRID III 50th dummy
In order to explore the difference between the head calibration of the THOR 50M dummy and the HYBRID III 50th dummy, the head structure of the two dummies are compared and analyzed, and then the calibration methods are compared, and the calibration performance indexes of the two dummies are compared. The results show that the head structure of the THOR 50M dummy is more complex than that of the HYBRID III 50th dummy, The head part of the THOR 50M dummy is three times that of the Hybrid III 50 dummy; The head calibration of the THOR 50M dummy consists of two parts, the forehead and the face, while the HYBRID III 50th dummy consists of only one part of the head. In the aspect of calibration performance index, the head calibration limits of the THOR 50M dummy and the HYBRID III 50th dummy are different, and the number of calibration indexes is also different. The calibration indexes of the THOR 50M dummy are more comprehensive.