超声多普勒空化气泡法测量流量

Y. Koike, T. Tsuyoshi, H. Kikura, M. Aritomi, M. Mori
{"title":"超声多普勒空化气泡法测量流量","authors":"Y. Koike, T. Tsuyoshi, H. Kikura, M. Aritomi, M. Mori","doi":"10.1109/ULTSYM.2002.1193458","DOIUrl":null,"url":null,"abstract":"The current principle of the flow velocity measurement method is based on the detection of the echoes of ultrasonic pulse Doppler method (UDM). However, in some applications, for example, a flow rate measurement in clean water, any particle does not exist in the flow and hence, the conventional UDM cannot be applied. The authors group proposed to employ the ultrasonic cavitation bubbles as reflectors in the flow measurement by UDM. The low frequency Langevin transducer attached to the outside wall of the pipe produces the cavitation bubbles in the flow. Therefore, UDM can be applied to the flow rate measurement without any suspending particle tracers. In this report, applicability and accuracy of the flow rate measurement are investigated in the case of the cavitations bubbles as reflectors. The measurement system with the cavitation production system is also designed and fabricated.","PeriodicalId":378705,"journal":{"name":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Flow rate measurement using ultrasonic Doppler method with cavitation bubbles\",\"authors\":\"Y. Koike, T. Tsuyoshi, H. Kikura, M. Aritomi, M. Mori\",\"doi\":\"10.1109/ULTSYM.2002.1193458\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The current principle of the flow velocity measurement method is based on the detection of the echoes of ultrasonic pulse Doppler method (UDM). However, in some applications, for example, a flow rate measurement in clean water, any particle does not exist in the flow and hence, the conventional UDM cannot be applied. The authors group proposed to employ the ultrasonic cavitation bubbles as reflectors in the flow measurement by UDM. The low frequency Langevin transducer attached to the outside wall of the pipe produces the cavitation bubbles in the flow. Therefore, UDM can be applied to the flow rate measurement without any suspending particle tracers. In this report, applicability and accuracy of the flow rate measurement are investigated in the case of the cavitations bubbles as reflectors. The measurement system with the cavitation production system is also designed and fabricated.\",\"PeriodicalId\":378705,\"journal\":{\"name\":\"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2002.1193458\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2002.1193458","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

目前的流速测量方法的原理是基于超声脉冲多普勒法(UDM)的回波检测。然而,在某些应用中,例如,在清洁水中的流量测量中,任何颗粒都不存在于流动中,因此,传统的UDM不能应用。本课题组提出将超声空化气泡作为反射体应用于UDM流量测量。附着在管道外壁的低频朗格万传感器在流动中产生空化气泡。因此,UDM可以应用于流量测量,不需要任何悬浮颗粒示踪剂。本文研究了以空化气泡为反射体的流量测量方法的适用性和准确性。设计并制作了带空化产生系统的测量系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Flow rate measurement using ultrasonic Doppler method with cavitation bubbles
The current principle of the flow velocity measurement method is based on the detection of the echoes of ultrasonic pulse Doppler method (UDM). However, in some applications, for example, a flow rate measurement in clean water, any particle does not exist in the flow and hence, the conventional UDM cannot be applied. The authors group proposed to employ the ultrasonic cavitation bubbles as reflectors in the flow measurement by UDM. The low frequency Langevin transducer attached to the outside wall of the pipe produces the cavitation bubbles in the flow. Therefore, UDM can be applied to the flow rate measurement without any suspending particle tracers. In this report, applicability and accuracy of the flow rate measurement are investigated in the case of the cavitations bubbles as reflectors. The measurement system with the cavitation production system is also designed and fabricated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信