基于石英晶体串联共振电容耦合电阻层析成像系统

Baoliang Wang, Sanfu Fu, H. Ji, Zhiyao Huang, Haiqing Li
{"title":"基于石英晶体串联共振电容耦合电阻层析成像系统","authors":"Baoliang Wang, Sanfu Fu, H. Ji, Zhiyao Huang, Haiqing Li","doi":"10.1109/IST.2012.6295539","DOIUrl":null,"url":null,"abstract":"The direct contact between the electrodes of the electrical resistance tomography and liquid may result in electrode corrosion and polarization, which limits the application of ERT in industry. Based on quartz crystal series resonance principle, this paper develops a capacitively coupled electrical resistance tomography system (CCERT). This system can measure the conductivity of liquid between electrodes without contact with the liquid. A 12-electrodes prototype system is developed and its data acquisition system is designed to implement the resistance measurement. To test the system performance, the experiment is implemented. Experiment results show that the conductivity distribution images inside the pipe can be reconstructed.","PeriodicalId":213330,"journal":{"name":"2012 IEEE International Conference on Imaging Systems and Techniques Proceedings","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Capacitively coupled electrical resistance tomography system based on quartz crystal series resonance\",\"authors\":\"Baoliang Wang, Sanfu Fu, H. Ji, Zhiyao Huang, Haiqing Li\",\"doi\":\"10.1109/IST.2012.6295539\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The direct contact between the electrodes of the electrical resistance tomography and liquid may result in electrode corrosion and polarization, which limits the application of ERT in industry. Based on quartz crystal series resonance principle, this paper develops a capacitively coupled electrical resistance tomography system (CCERT). This system can measure the conductivity of liquid between electrodes without contact with the liquid. A 12-electrodes prototype system is developed and its data acquisition system is designed to implement the resistance measurement. To test the system performance, the experiment is implemented. Experiment results show that the conductivity distribution images inside the pipe can be reconstructed.\",\"PeriodicalId\":213330,\"journal\":{\"name\":\"2012 IEEE International Conference on Imaging Systems and Techniques Proceedings\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-07-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Conference on Imaging Systems and Techniques Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IST.2012.6295539\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Conference on Imaging Systems and Techniques Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IST.2012.6295539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电阻层析成像的电极与液体的直接接触可能导致电极腐蚀和极化,这限制了电阻层析成像在工业上的应用。基于石英晶体串联谐振原理,研制了电容耦合电阻层析成像系统(CCERT)。该系统可以在不接触液体的情况下测量电极间液体的电导率。开发了一个12电极的原型系统,并设计了其数据采集系统来实现电阻测量。为了测试系统的性能,进行了实验。实验结果表明,该方法可以重建管道内部的电导率分布图像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Capacitively coupled electrical resistance tomography system based on quartz crystal series resonance
The direct contact between the electrodes of the electrical resistance tomography and liquid may result in electrode corrosion and polarization, which limits the application of ERT in industry. Based on quartz crystal series resonance principle, this paper develops a capacitively coupled electrical resistance tomography system (CCERT). This system can measure the conductivity of liquid between electrodes without contact with the liquid. A 12-electrodes prototype system is developed and its data acquisition system is designed to implement the resistance measurement. To test the system performance, the experiment is implemented. Experiment results show that the conductivity distribution images inside the pipe can be reconstructed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信