环形通道中Brno CHF实验回路结果的验证

Ladislav Suk, Kamil Števanka, T. Petrosyan, K. Katovský
{"title":"环形通道中Brno CHF实验回路结果的验证","authors":"Ladislav Suk, Kamil Števanka, T. Petrosyan, K. Katovský","doi":"10.1109/EPE51172.2020.9269190","DOIUrl":null,"url":null,"abstract":"This study presents an experimental investigation of critical heat flux on Inconel 625 and compares the results with experimental work as well as correlations from literature. Tests were performed on the loop at pressure up to 300 kPa and mass flux rate up to 0.4 kg/(m2·s). The heated tube was 380 mm long with an outside and inside diameter of 9.14 mm and 8 mm respectively. The boiling crisis was achieved using DC heating and the temperature of test section was measured using K-type thermocouples. Finally, recorded values were compared to and validated with the analytical correlations from scientific literature and other experimental results.","PeriodicalId":177031,"journal":{"name":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Validation of Results of Brno CHF Experimental Loop in Annular Channel\",\"authors\":\"Ladislav Suk, Kamil Števanka, T. Petrosyan, K. Katovský\",\"doi\":\"10.1109/EPE51172.2020.9269190\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study presents an experimental investigation of critical heat flux on Inconel 625 and compares the results with experimental work as well as correlations from literature. Tests were performed on the loop at pressure up to 300 kPa and mass flux rate up to 0.4 kg/(m2·s). The heated tube was 380 mm long with an outside and inside diameter of 9.14 mm and 8 mm respectively. The boiling crisis was achieved using DC heating and the temperature of test section was measured using K-type thermocouples. Finally, recorded values were compared to and validated with the analytical correlations from scientific literature and other experimental results.\",\"PeriodicalId\":177031,\"journal\":{\"name\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE51172.2020.9269190\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE51172.2020.9269190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文对Inconel 625的临界热流密度进行了实验研究,并与实验结果和文献的相关性进行了比较。在压力高达300 kPa、质量通量高达0.4 kg/(m2·s)的回路上进行了试验。加热管长380 mm,外径9.14 mm,内径8 mm。采用直流加热实现沸腾危机,采用k型热电偶测量试验段温度。最后,将记录值与科学文献和其他实验结果的分析相关性进行比较并验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of Results of Brno CHF Experimental Loop in Annular Channel
This study presents an experimental investigation of critical heat flux on Inconel 625 and compares the results with experimental work as well as correlations from literature. Tests were performed on the loop at pressure up to 300 kPa and mass flux rate up to 0.4 kg/(m2·s). The heated tube was 380 mm long with an outside and inside diameter of 9.14 mm and 8 mm respectively. The boiling crisis was achieved using DC heating and the temperature of test section was measured using K-type thermocouples. Finally, recorded values were compared to and validated with the analytical correlations from scientific literature and other experimental results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信