用实验模型测定受污染暖通空调绝缘子在电闪络过程中的离子迁移率

B. Zegnini, D. Mahi, A. Chaker
{"title":"用实验模型测定受污染暖通空调绝缘子在电闪络过程中的离子迁移率","authors":"B. Zegnini, D. Mahi, A. Chaker","doi":"10.1109/CEIDP.2003.1254858","DOIUrl":null,"url":null,"abstract":"During electric flashover process its difficult to determine the real values of ions mobility, because we did not known the nature of different ions ejected forward the leader of the discharge. Using results of time to flashover measurements against applied voltage which carried out under AC with the experimental set up. In this paper the regression method is used to model accurately the relationship between flashover time and insulators parameters in order to calculate the ions mobility. Moreover the results obtained are discussed. The present study indicates that the different values of ions mobility are a good concordance between this model and those obtained in humid air and water steam.","PeriodicalId":306575,"journal":{"name":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ions mobility determinations on polluted HVAC insulators during electric flashover using experimental model\",\"authors\":\"B. Zegnini, D. Mahi, A. Chaker\",\"doi\":\"10.1109/CEIDP.2003.1254858\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"During electric flashover process its difficult to determine the real values of ions mobility, because we did not known the nature of different ions ejected forward the leader of the discharge. Using results of time to flashover measurements against applied voltage which carried out under AC with the experimental set up. In this paper the regression method is used to model accurately the relationship between flashover time and insulators parameters in order to calculate the ions mobility. Moreover the results obtained are discussed. The present study indicates that the different values of ions mobility are a good concordance between this model and those obtained in humid air and water steam.\",\"PeriodicalId\":306575,\"journal\":{\"name\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2003.1254858\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2003.1254858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在电闪过程中,离子迁移率的真实值很难确定,因为我们不知道放电前导喷出的不同离子的性质。利用实验装置在交流条件下对外加电压的闪络时间测量结果。本文采用回归方法准确地模拟了闪络时间与绝缘子参数之间的关系,从而计算出离子迁移率。并对所得结果进行了讨论。本研究表明,该模型中离子迁移率的不同值与在潮湿空气和水蒸气中得到的值有很好的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ions mobility determinations on polluted HVAC insulators during electric flashover using experimental model
During electric flashover process its difficult to determine the real values of ions mobility, because we did not known the nature of different ions ejected forward the leader of the discharge. Using results of time to flashover measurements against applied voltage which carried out under AC with the experimental set up. In this paper the regression method is used to model accurately the relationship between flashover time and insulators parameters in order to calculate the ions mobility. Moreover the results obtained are discussed. The present study indicates that the different values of ions mobility are a good concordance between this model and those obtained in humid air and water steam.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信