A. Mohammad, S. Mat, M. Sulaiman, K. Sopian, Abduljalil A. Al-abidi
{"title":"在吉隆坡运行的直接蒸发冷却器的实验性能","authors":"A. Mohammad, S. Mat, M. Sulaiman, K. Sopian, Abduljalil A. Al-abidi","doi":"10.5383/ijtee.06.01.003","DOIUrl":null,"url":null,"abstract":"The present work presents an experimental investigation on the performance of a direct evaporative cooler in hot and humid regions. The experimental study is based on weather data from Kuala Lumpur, Malaysia. The direct evaporative cooler consists of a cellulose pad with a surface area per unit volume ratio of 100 m2 /m3 . The performance of the evaporative cooler is evaluated using the output temperature, saturation efficiency, and cooling capacity. The output temperature of the air varies between 27.5°C and 29.4° C, while the cooling capacity is between 1.384 kW and 5.358 kW.","PeriodicalId":429709,"journal":{"name":"International Journal of Thermal and Environmental Engineering","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Experimental Performance of a Direct Evaporative Cooler Operating in Kuala Lumpur\",\"authors\":\"A. Mohammad, S. Mat, M. Sulaiman, K. Sopian, Abduljalil A. Al-abidi\",\"doi\":\"10.5383/ijtee.06.01.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present work presents an experimental investigation on the performance of a direct evaporative cooler in hot and humid regions. The experimental study is based on weather data from Kuala Lumpur, Malaysia. The direct evaporative cooler consists of a cellulose pad with a surface area per unit volume ratio of 100 m2 /m3 . The performance of the evaporative cooler is evaluated using the output temperature, saturation efficiency, and cooling capacity. The output temperature of the air varies between 27.5°C and 29.4° C, while the cooling capacity is between 1.384 kW and 5.358 kW.\",\"PeriodicalId\":429709,\"journal\":{\"name\":\"International Journal of Thermal and Environmental Engineering\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Thermal and Environmental Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5383/ijtee.06.01.003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Thermal and Environmental Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5383/ijtee.06.01.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental Performance of a Direct Evaporative Cooler Operating in Kuala Lumpur
The present work presents an experimental investigation on the performance of a direct evaporative cooler in hot and humid regions. The experimental study is based on weather data from Kuala Lumpur, Malaysia. The direct evaporative cooler consists of a cellulose pad with a surface area per unit volume ratio of 100 m2 /m3 . The performance of the evaporative cooler is evaluated using the output temperature, saturation efficiency, and cooling capacity. The output temperature of the air varies between 27.5°C and 29.4° C, while the cooling capacity is between 1.384 kW and 5.358 kW.