不间断电源概述

M. S. Racine, James D. Parham, Muhammad H. Rashid
{"title":"不间断电源概述","authors":"M. S. Racine, James D. Parham, Muhammad H. Rashid","doi":"10.1109/NAPS.2005.1560518","DOIUrl":null,"url":null,"abstract":"An uninterruptible power supply (UPS) can range from a 9 volt battery all the way to an extremely large and costly battery system. The UPS sits between a power supply such as a wall outlet and a device like a computer to prevent undesired features that can occur within the power source such as outages, sags, surges, and bad harmonics from the supply to avoid a negative impact on the device. There are several types of UPSes as they strictly relate to computers. The standby UPS is a battery backup to fill in the void of power loss, while the ferroresonant stand by couples the battery back up with the power supply by a transformer, where the transformer acts as a buffer from the power supply to the stand by supply. The line interactive UPS uses an inverter converter only, with a power supply the stand by battery is charged up, and with a loss of the primary power supply, the inverter converter switches over to the battery back up with a much quicker switching time that the stand by UPS.","PeriodicalId":101495,"journal":{"name":"Proceedings of the 37th Annual North American Power Symposium, 2005.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2005-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"74","resultStr":"{\"title\":\"An overview of uninterruptible power supplies\",\"authors\":\"M. S. Racine, James D. Parham, Muhammad H. Rashid\",\"doi\":\"10.1109/NAPS.2005.1560518\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An uninterruptible power supply (UPS) can range from a 9 volt battery all the way to an extremely large and costly battery system. The UPS sits between a power supply such as a wall outlet and a device like a computer to prevent undesired features that can occur within the power source such as outages, sags, surges, and bad harmonics from the supply to avoid a negative impact on the device. There are several types of UPSes as they strictly relate to computers. The standby UPS is a battery backup to fill in the void of power loss, while the ferroresonant stand by couples the battery back up with the power supply by a transformer, where the transformer acts as a buffer from the power supply to the stand by supply. The line interactive UPS uses an inverter converter only, with a power supply the stand by battery is charged up, and with a loss of the primary power supply, the inverter converter switches over to the battery back up with a much quicker switching time that the stand by UPS.\",\"PeriodicalId\":101495,\"journal\":{\"name\":\"Proceedings of the 37th Annual North American Power Symposium, 2005.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"74\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 37th Annual North American Power Symposium, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2005.1560518\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 37th Annual North American Power Symposium, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2005.1560518","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 74

摘要

不间断电源(UPS)可以是9伏的电池,也可以是非常大且昂贵的电池系统。UPS位于电源(如墙壁插座)和设备(如计算机)之间,以防止电源中可能出现的不希望出现的特性,例如断电,下垂,浪涌和电源的不良谐波,以避免对设备产生负面影响。有几种类型的ups,因为它们严格地与计算机相关。备用UPS是电池备用,以填补电力损失的空白,而铁谐振备用UPS通过变压器将备用电池与电源耦合,其中变压器起到从电源到备用电源的缓冲作用。线路互动式UPS仅使用逆变器转换器,有了电源,备用电池就可以充电,在失去主电源的情况下,逆变器转换器切换到备用电池,切换时间比备用UPS快得多。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An overview of uninterruptible power supplies
An uninterruptible power supply (UPS) can range from a 9 volt battery all the way to an extremely large and costly battery system. The UPS sits between a power supply such as a wall outlet and a device like a computer to prevent undesired features that can occur within the power source such as outages, sags, surges, and bad harmonics from the supply to avoid a negative impact on the device. There are several types of UPSes as they strictly relate to computers. The standby UPS is a battery backup to fill in the void of power loss, while the ferroresonant stand by couples the battery back up with the power supply by a transformer, where the transformer acts as a buffer from the power supply to the stand by supply. The line interactive UPS uses an inverter converter only, with a power supply the stand by battery is charged up, and with a loss of the primary power supply, the inverter converter switches over to the battery back up with a much quicker switching time that the stand by UPS.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信