集成光眼技术(iLeyeT)检测血型试验中红细胞凝集

Yaw-Jen Chang, Walter H. Chang, Yu-Te Lin
{"title":"集成光眼技术(iLeyeT)检测血型试验中红细胞凝集","authors":"Yaw-Jen Chang, Walter H. Chang, Yu-Te Lin","doi":"10.1109/ISBB.2014.6820952","DOIUrl":null,"url":null,"abstract":"Blood typing is a critical test in many medical procedures, especially for blood transfusion. Incompatible red blood cells (RBCs) in transfusion might result in intravascular hemolysis and even cause recipient's death. The test result of blood typing can be determined by observing the agglutination of RBCs. In this study, a novel method for determining the extent of RBC agglutination using the integrated Light-Eye Technology (iLeyeT) system is presented. Blood typing tests based on manual polybrene technique were carried out in microchambers. If RBC agglutination occurs, the laser beam provided by the iLeyeT system is blocked and a reduced laser power is measured. The experimental results show that green laser beam had better performance and successful determinations of RBC agglutinations in blood typing tests were achieved by means of iLeyeT system.","PeriodicalId":265886,"journal":{"name":"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Detection of RBC agglutination in blood typing test using integrated Light-Eye-Technology (iLeyeT)\",\"authors\":\"Yaw-Jen Chang, Walter H. Chang, Yu-Te Lin\",\"doi\":\"10.1109/ISBB.2014.6820952\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Blood typing is a critical test in many medical procedures, especially for blood transfusion. Incompatible red blood cells (RBCs) in transfusion might result in intravascular hemolysis and even cause recipient's death. The test result of blood typing can be determined by observing the agglutination of RBCs. In this study, a novel method for determining the extent of RBC agglutination using the integrated Light-Eye Technology (iLeyeT) system is presented. Blood typing tests based on manual polybrene technique were carried out in microchambers. If RBC agglutination occurs, the laser beam provided by the iLeyeT system is blocked and a reduced laser power is measured. The experimental results show that green laser beam had better performance and successful determinations of RBC agglutinations in blood typing tests were achieved by means of iLeyeT system.\",\"PeriodicalId\":265886,\"journal\":{\"name\":\"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBB.2014.6820952\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBB.2014.6820952","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在许多医疗程序中,尤其是输血过程中,血型是一项至关重要的测试。输血中不相容的红细胞可能导致血管内溶血,甚至导致受者死亡。通过观察红细胞凝集情况,可以确定血型的检测结果。在这项研究中,提出了一种利用集成光眼技术(iLeyeT)系统确定红细胞凝集程度的新方法。在微室中进行了基于人工聚苯乙烯技术的血型检测。如果发生红细胞凝集,则iLeyeT系统提供的激光束被阻挡,并测量降低的激光功率。实验结果表明,绿色激光束具有较好的性能,利用iLeyeT系统可以成功地测定血型试验中的红细胞凝集。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detection of RBC agglutination in blood typing test using integrated Light-Eye-Technology (iLeyeT)
Blood typing is a critical test in many medical procedures, especially for blood transfusion. Incompatible red blood cells (RBCs) in transfusion might result in intravascular hemolysis and even cause recipient's death. The test result of blood typing can be determined by observing the agglutination of RBCs. In this study, a novel method for determining the extent of RBC agglutination using the integrated Light-Eye Technology (iLeyeT) system is presented. Blood typing tests based on manual polybrene technique were carried out in microchambers. If RBC agglutination occurs, the laser beam provided by the iLeyeT system is blocked and a reduced laser power is measured. The experimental results show that green laser beam had better performance and successful determinations of RBC agglutinations in blood typing tests were achieved by means of iLeyeT system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信