网络分析器功能模拟器

P. Malmlof
{"title":"网络分析器功能模拟器","authors":"P. Malmlof","doi":"10.1109/ARFTGF.2004.1427593","DOIUrl":null,"url":null,"abstract":"In this paper, a method is described that provides vector network analyzer (VNA) functionality without the introduction of a VNA to the test system. In many cases, the amount of testing that requires a VNA is very limited, and most of the testing requires other instruments. In some cases, the required measurements have been performed with a setup consisting of a signal generator, directional couplers and a power meter. This method usually results in extremely poor accuracy. We have to have a signal source that can provide the required modulated signals for testing, and we have to have a vector signal analyzer (VSA) that can perform spectral measurements as well as vector error measurements etc. By utilizing the capabilities of these instruments we can achieve the wanted VNA functionality, with good enough accuracy for several of our applications.","PeriodicalId":273791,"journal":{"name":"64th ARFTG Microwave Measurements Conference, Fall 2004.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Network analyzer functionality simulator\",\"authors\":\"P. Malmlof\",\"doi\":\"10.1109/ARFTGF.2004.1427593\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a method is described that provides vector network analyzer (VNA) functionality without the introduction of a VNA to the test system. In many cases, the amount of testing that requires a VNA is very limited, and most of the testing requires other instruments. In some cases, the required measurements have been performed with a setup consisting of a signal generator, directional couplers and a power meter. This method usually results in extremely poor accuracy. We have to have a signal source that can provide the required modulated signals for testing, and we have to have a vector signal analyzer (VSA) that can perform spectral measurements as well as vector error measurements etc. By utilizing the capabilities of these instruments we can achieve the wanted VNA functionality, with good enough accuracy for several of our applications.\",\"PeriodicalId\":273791,\"journal\":{\"name\":\"64th ARFTG Microwave Measurements Conference, Fall 2004.\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"64th ARFTG Microwave Measurements Conference, Fall 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ARFTGF.2004.1427593\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"64th ARFTG Microwave Measurements Conference, Fall 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTGF.2004.1427593","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文描述了一种无需在测试系统中引入矢量网络分析仪(VNA)就能提供矢量网络分析仪功能的方法。在许多情况下,需要VNA的测试量非常有限,大多数测试需要其他仪器。在某些情况下,需要使用由信号发生器、定向耦合器和功率计组成的装置进行所需的测量。这种方法通常导致精度极差。我们必须有一个信号源,可以提供所需的调制信号进行测试,我们必须有一个矢量信号分析仪(VSA),可以执行频谱测量以及矢量误差测量等。通过利用这些仪器的功能,我们可以实现所需的VNA功能,并为我们的几个应用提供足够好的精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Network analyzer functionality simulator
In this paper, a method is described that provides vector network analyzer (VNA) functionality without the introduction of a VNA to the test system. In many cases, the amount of testing that requires a VNA is very limited, and most of the testing requires other instruments. In some cases, the required measurements have been performed with a setup consisting of a signal generator, directional couplers and a power meter. This method usually results in extremely poor accuracy. We have to have a signal source that can provide the required modulated signals for testing, and we have to have a vector signal analyzer (VSA) that can perform spectral measurements as well as vector error measurements etc. By utilizing the capabilities of these instruments we can achieve the wanted VNA functionality, with good enough accuracy for several of our applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信