{"title":"用于可穿戴系统生物信号测量的动态运动分析","authors":"Y. Kim, Jeun-Woo Lee","doi":"10.1109/CIMA.2005.1662314","DOIUrl":null,"url":null,"abstract":"When measuring a bio-signal at wearable system, it is very important that considering variation differs from people's posture and the gain of the signal acquired by the position of a sensor. In this paper, framework for resolving the bio-signal with a dynamic motion is shown, and we suggest an analyzed data by man's motion and posture. The distortion mixed with the bio-signal is classed by two factors that one is motion artifact produced by motion of people, other is variation of signal by change of sensor position. In order to remove these distortions, we should have to quantify and analyze the signal being measured in given condition","PeriodicalId":306045,"journal":{"name":"2005 ICSC Congress on Computational Intelligence Methods and Applications","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of the Dynamic Motion for Biosignal Measurement in Wearable system\",\"authors\":\"Y. Kim, Jeun-Woo Lee\",\"doi\":\"10.1109/CIMA.2005.1662314\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When measuring a bio-signal at wearable system, it is very important that considering variation differs from people's posture and the gain of the signal acquired by the position of a sensor. In this paper, framework for resolving the bio-signal with a dynamic motion is shown, and we suggest an analyzed data by man's motion and posture. The distortion mixed with the bio-signal is classed by two factors that one is motion artifact produced by motion of people, other is variation of signal by change of sensor position. In order to remove these distortions, we should have to quantify and analyze the signal being measured in given condition\",\"PeriodicalId\":306045,\"journal\":{\"name\":\"2005 ICSC Congress on Computational Intelligence Methods and Applications\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 ICSC Congress on Computational Intelligence Methods and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIMA.2005.1662314\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 ICSC Congress on Computational Intelligence Methods and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIMA.2005.1662314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of the Dynamic Motion for Biosignal Measurement in Wearable system
When measuring a bio-signal at wearable system, it is very important that considering variation differs from people's posture and the gain of the signal acquired by the position of a sensor. In this paper, framework for resolving the bio-signal with a dynamic motion is shown, and we suggest an analyzed data by man's motion and posture. The distortion mixed with the bio-signal is classed by two factors that one is motion artifact produced by motion of people, other is variation of signal by change of sensor position. In order to remove these distortions, we should have to quantify and analyze the signal being measured in given condition