{"title":"焦耳-汤姆逊冷却器中回热式换热器的建模","authors":"K. Ng, JinBao Wang, H. Xue","doi":"10.1115/imece2001/htd-24278","DOIUrl":null,"url":null,"abstract":"\n To develop effective heat exchangers for miniature and micro Joule-Thomson (J-T) cooling system, the performance of a recuperative heat exchanger is analyzed and evaluated. The evaluation is based on a theoretical model of the Hampson-type counter-flow heat exchanger. The effect of the pressure and temperature-dependent properties and longitudinal heat conduction are considered. The results of the numerical simulation are validated with the corresponding experimental measurements. The performance of the heat exchanger on effectiveness, flow and various heat conduction losses as well as liquefied yield fraction are analyzed and discussed. The simulation model provides a useful tool for miniature J-T cooler design.","PeriodicalId":426926,"journal":{"name":"Heat Transfer: Volume 4 — Combustion and Energy Systems","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modeling of Recuperative Heat Exchanger in a Joule-Thomson Cooler\",\"authors\":\"K. Ng, JinBao Wang, H. Xue\",\"doi\":\"10.1115/imece2001/htd-24278\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n To develop effective heat exchangers for miniature and micro Joule-Thomson (J-T) cooling system, the performance of a recuperative heat exchanger is analyzed and evaluated. The evaluation is based on a theoretical model of the Hampson-type counter-flow heat exchanger. The effect of the pressure and temperature-dependent properties and longitudinal heat conduction are considered. The results of the numerical simulation are validated with the corresponding experimental measurements. The performance of the heat exchanger on effectiveness, flow and various heat conduction losses as well as liquefied yield fraction are analyzed and discussed. The simulation model provides a useful tool for miniature J-T cooler design.\",\"PeriodicalId\":426926,\"journal\":{\"name\":\"Heat Transfer: Volume 4 — Combustion and Energy Systems\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heat Transfer: Volume 4 — Combustion and Energy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/imece2001/htd-24278\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heat Transfer: Volume 4 — Combustion and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2001/htd-24278","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modeling of Recuperative Heat Exchanger in a Joule-Thomson Cooler
To develop effective heat exchangers for miniature and micro Joule-Thomson (J-T) cooling system, the performance of a recuperative heat exchanger is analyzed and evaluated. The evaluation is based on a theoretical model of the Hampson-type counter-flow heat exchanger. The effect of the pressure and temperature-dependent properties and longitudinal heat conduction are considered. The results of the numerical simulation are validated with the corresponding experimental measurements. The performance of the heat exchanger on effectiveness, flow and various heat conduction losses as well as liquefied yield fraction are analyzed and discussed. The simulation model provides a useful tool for miniature J-T cooler design.