G. Filacchione, F. Capaccioni, F. Altieri, C. Carli, L. Tommasi, I. F. Veltroni, M. Dami, G. Aroldi, D. Borrelli, A. Barbis, M. Baroni, G. Pastorini, R. Mugnuolo, G. Cremonese
{"title":"SIMBIO-SYS/VIHI光谱仪噪声等效光谱辐射的测量","authors":"G. Filacchione, F. Capaccioni, F. Altieri, C. Carli, L. Tommasi, I. F. Veltroni, M. Dami, G. Aroldi, D. Borrelli, A. Barbis, M. Baroni, G. Pastorini, R. Mugnuolo, G. Cremonese","doi":"10.1109/METROAEROSPACE.2018.8453616","DOIUrl":null,"url":null,"abstract":"We report about the measurement of the Noise-Equivalent Spectral Radiance (NESR) of the VIHI imaging spectromter aboard ESA's Bepi Colombo mission to Mercury. The knowledge of the NESR allows to determine the capability of an optical detector to measure faint signals. A description of the setup used to determine the NESR during the prelaunch calibration campaign is given. The processing of the data collected at various operative temperatures and integration times is described. The sensitivity study of the NESR has been performed at the expected detector's temperatures and integration times with the goal to determine the minimum spectral radiance at which VIHI is sensitive during the different observation phases of the mission. A simulation of the expected Signal-to-Noise Ratio (SNR) of VIHI during the different orbital phases is provided.","PeriodicalId":142603,"journal":{"name":"2018 5th IEEE International Workshop on Metrology for AeroSpace (MetroAeroSpace)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"The Measurement of the Noise-Equivalent Spectral Radiance of SIMBIO-SYS/VIHI Spectrometer\",\"authors\":\"G. Filacchione, F. Capaccioni, F. Altieri, C. Carli, L. Tommasi, I. F. Veltroni, M. Dami, G. Aroldi, D. Borrelli, A. Barbis, M. Baroni, G. Pastorini, R. Mugnuolo, G. Cremonese\",\"doi\":\"10.1109/METROAEROSPACE.2018.8453616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report about the measurement of the Noise-Equivalent Spectral Radiance (NESR) of the VIHI imaging spectromter aboard ESA's Bepi Colombo mission to Mercury. The knowledge of the NESR allows to determine the capability of an optical detector to measure faint signals. A description of the setup used to determine the NESR during the prelaunch calibration campaign is given. The processing of the data collected at various operative temperatures and integration times is described. The sensitivity study of the NESR has been performed at the expected detector's temperatures and integration times with the goal to determine the minimum spectral radiance at which VIHI is sensitive during the different observation phases of the mission. A simulation of the expected Signal-to-Noise Ratio (SNR) of VIHI during the different orbital phases is provided.\",\"PeriodicalId\":142603,\"journal\":{\"name\":\"2018 5th IEEE International Workshop on Metrology for AeroSpace (MetroAeroSpace)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 5th IEEE International Workshop on Metrology for AeroSpace (MetroAeroSpace)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/METROAEROSPACE.2018.8453616\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 5th IEEE International Workshop on Metrology for AeroSpace (MetroAeroSpace)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/METROAEROSPACE.2018.8453616","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Measurement of the Noise-Equivalent Spectral Radiance of SIMBIO-SYS/VIHI Spectrometer
We report about the measurement of the Noise-Equivalent Spectral Radiance (NESR) of the VIHI imaging spectromter aboard ESA's Bepi Colombo mission to Mercury. The knowledge of the NESR allows to determine the capability of an optical detector to measure faint signals. A description of the setup used to determine the NESR during the prelaunch calibration campaign is given. The processing of the data collected at various operative temperatures and integration times is described. The sensitivity study of the NESR has been performed at the expected detector's temperatures and integration times with the goal to determine the minimum spectral radiance at which VIHI is sensitive during the different observation phases of the mission. A simulation of the expected Signal-to-Noise Ratio (SNR) of VIHI during the different orbital phases is provided.