Xinlei Zhu, Ran Zhang, Haiyun Luo, Shen Zhao, X. Zou, Xinxin Wang
{"title":"x射线背光初期的单线和多线z夹紧","authors":"Xinlei Zhu, Ran Zhang, Haiyun Luo, Shen Zhao, X. Zou, Xinxin Wang","doi":"10.1109/IPMHVC.2012.6518809","DOIUrl":null,"url":null,"abstract":"The initial stage of single-wire and multi-wire Z-pinch were investigated by X-ray backlighting using an X-pinch as the soft X-ray source. The experiments were carried out on the pulsed power generator PPG-I (400kA/500kV/100ns) which was designed and constructed by Tsinghua University. The source X-pinch and object single-wire or multi-wire Z-pinch are installed in the place of a current-return rod or the center between the anode and the cathode, respectively. The X-ray films with high resolution and high sensitivity were used to record the results. A resistive current probe and a Rogowski coil were used to monitor the current, and a step wedge filter was designed to measure the mass ablation rate of the thin wire. By a large number of imaging experiments, the time sequence of images for the coronal plasma formation, the inter-wire plasma merging, and the development of plasma instabilities of Z-pinch as well as some important quantitative parameters like mass ablation rate and core expansion rate were obtained.","PeriodicalId":228441,"journal":{"name":"2012 IEEE International Power Modulator and High Voltage Conference (IPMHVC)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"X-ray backlighting of the initial stage of single-wire and multi-wire Z-pinch\",\"authors\":\"Xinlei Zhu, Ran Zhang, Haiyun Luo, Shen Zhao, X. Zou, Xinxin Wang\",\"doi\":\"10.1109/IPMHVC.2012.6518809\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The initial stage of single-wire and multi-wire Z-pinch were investigated by X-ray backlighting using an X-pinch as the soft X-ray source. The experiments were carried out on the pulsed power generator PPG-I (400kA/500kV/100ns) which was designed and constructed by Tsinghua University. The source X-pinch and object single-wire or multi-wire Z-pinch are installed in the place of a current-return rod or the center between the anode and the cathode, respectively. The X-ray films with high resolution and high sensitivity were used to record the results. A resistive current probe and a Rogowski coil were used to monitor the current, and a step wedge filter was designed to measure the mass ablation rate of the thin wire. By a large number of imaging experiments, the time sequence of images for the coronal plasma formation, the inter-wire plasma merging, and the development of plasma instabilities of Z-pinch as well as some important quantitative parameters like mass ablation rate and core expansion rate were obtained.\",\"PeriodicalId\":228441,\"journal\":{\"name\":\"2012 IEEE International Power Modulator and High Voltage Conference (IPMHVC)\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Power Modulator and High Voltage Conference (IPMHVC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPMHVC.2012.6518809\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Power Modulator and High Voltage Conference (IPMHVC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPMHVC.2012.6518809","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
X-ray backlighting of the initial stage of single-wire and multi-wire Z-pinch
The initial stage of single-wire and multi-wire Z-pinch were investigated by X-ray backlighting using an X-pinch as the soft X-ray source. The experiments were carried out on the pulsed power generator PPG-I (400kA/500kV/100ns) which was designed and constructed by Tsinghua University. The source X-pinch and object single-wire or multi-wire Z-pinch are installed in the place of a current-return rod or the center between the anode and the cathode, respectively. The X-ray films with high resolution and high sensitivity were used to record the results. A resistive current probe and a Rogowski coil were used to monitor the current, and a step wedge filter was designed to measure the mass ablation rate of the thin wire. By a large number of imaging experiments, the time sequence of images for the coronal plasma formation, the inter-wire plasma merging, and the development of plasma instabilities of Z-pinch as well as some important quantitative parameters like mass ablation rate and core expansion rate were obtained.