冠状窦闭塞血流动力学:线性模型

A. Mo, Y. Sun
{"title":"冠状窦闭塞血流动力学:线性模型","authors":"A. Mo, Y. Sun","doi":"10.1109/NEBC.1988.19406","DOIUrl":null,"url":null,"abstract":"The coronary sinus occlusion pressure exhibits complicated frequency characteristics which can be modeled by either a nonlinear system approach or a high-order LTI (linear time-invariant) system approach. The LTI system presents a superior modeling methodology, due to the applicability of powerful analytical tools such as Fourier analysis. Using linear system identification techniques, a fifth-order LTI system was obtained to characterize coronary sinus occlusion pressure waveforms. Linear systems of lower order were found to have insufficient degree of freedom to model the hemodynamics of the coronary sinus occlusion. The resulting model from the systematic identification process was stable within a broad range of variations of heart rate and time constant of the coronary sinus occlusion pressure. This model provides a mathematical basis to study distributive properties in the coronary venous circulation and to optimize various treatment procedures of myocardium diseases via the coronary sinus.<<ETX>>","PeriodicalId":165980,"journal":{"name":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hemodynamics of coronary sinus occlusion: a linear model\",\"authors\":\"A. Mo, Y. Sun\",\"doi\":\"10.1109/NEBC.1988.19406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The coronary sinus occlusion pressure exhibits complicated frequency characteristics which can be modeled by either a nonlinear system approach or a high-order LTI (linear time-invariant) system approach. The LTI system presents a superior modeling methodology, due to the applicability of powerful analytical tools such as Fourier analysis. Using linear system identification techniques, a fifth-order LTI system was obtained to characterize coronary sinus occlusion pressure waveforms. Linear systems of lower order were found to have insufficient degree of freedom to model the hemodynamics of the coronary sinus occlusion. The resulting model from the systematic identification process was stable within a broad range of variations of heart rate and time constant of the coronary sinus occlusion pressure. This model provides a mathematical basis to study distributive properties in the coronary venous circulation and to optimize various treatment procedures of myocardium diseases via the coronary sinus.<<ETX>>\",\"PeriodicalId\":165980,\"journal\":{\"name\":\"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBC.1988.19406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1988.19406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

冠状窦闭塞压力具有复杂的频率特性,可以采用非线性系统方法或高阶线性时不变系统方法进行建模。由于傅立叶分析等强大的分析工具的适用性,LTI系统提供了优越的建模方法。利用线性系统识别技术,获得了一个五阶LTI系统来表征冠状窦闭塞压力波形。低阶线性系统被发现自由度不足以模拟冠状窦阻塞的血流动力学。系统识别过程得到的模型在心率和冠状窦闭塞压时间常数的大范围变化范围内是稳定的。该模型为研究冠状静脉循环的分布特性和优化经冠状静脉窦治疗心肌疾病的各种方法提供了数学基础
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hemodynamics of coronary sinus occlusion: a linear model
The coronary sinus occlusion pressure exhibits complicated frequency characteristics which can be modeled by either a nonlinear system approach or a high-order LTI (linear time-invariant) system approach. The LTI system presents a superior modeling methodology, due to the applicability of powerful analytical tools such as Fourier analysis. Using linear system identification techniques, a fifth-order LTI system was obtained to characterize coronary sinus occlusion pressure waveforms. Linear systems of lower order were found to have insufficient degree of freedom to model the hemodynamics of the coronary sinus occlusion. The resulting model from the systematic identification process was stable within a broad range of variations of heart rate and time constant of the coronary sinus occlusion pressure. This model provides a mathematical basis to study distributive properties in the coronary venous circulation and to optimize various treatment procedures of myocardium diseases via the coronary sinus.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信