{"title":"验证Serpent2代码用于VR-1反应堆堆芯计算","authors":"O. Novak, J. Frybort","doi":"10.1109/EPE51172.2020.9269203","DOIUrl":null,"url":null,"abstract":"The VR-1 reactor core safety characteristics calculations are performed by standardized MCNP code, however due to license requirements, it is desired to replace it by the Serpent2 code. In order to do that, Serpent2 calculation must be standardized by State office of nuclear safety. Comparison of Serpent2 and MCNP multiplication factors for several reactor cores is presented to demonstrate the capability and accuracy of Serpent2 results. In addition to this, Serpent2 calculation setup is tested and the impact of different nuclear data libraries is examined. The comparison of results from Serpent2 and standardized MCNP calculation proved that results are similar and therefore the Serpent2 code can be used for the VR-1 reactor core calculations, especially for criticality predictions.","PeriodicalId":177031,"journal":{"name":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of the Serpent2 code for the VR-1 reactor core calculation\",\"authors\":\"O. Novak, J. Frybort\",\"doi\":\"10.1109/EPE51172.2020.9269203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The VR-1 reactor core safety characteristics calculations are performed by standardized MCNP code, however due to license requirements, it is desired to replace it by the Serpent2 code. In order to do that, Serpent2 calculation must be standardized by State office of nuclear safety. Comparison of Serpent2 and MCNP multiplication factors for several reactor cores is presented to demonstrate the capability and accuracy of Serpent2 results. In addition to this, Serpent2 calculation setup is tested and the impact of different nuclear data libraries is examined. The comparison of results from Serpent2 and standardized MCNP calculation proved that results are similar and therefore the Serpent2 code can be used for the VR-1 reactor core calculations, especially for criticality predictions.\",\"PeriodicalId\":177031,\"journal\":{\"name\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE51172.2020.9269203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE51172.2020.9269203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

VR-1反应堆堆芯安全特性计算由标准化的MCNP代码执行,但由于许可证要求,希望用Serpent2代码取代它。为了做到这一点,Serpent2的计算必须由国家核安全办公室标准化。通过对几个堆芯的Serpent2和MCNP倍增因子的比较,证明了Serpent2结果的能力和准确性。除此之外,还测试了Serpent2计算设置,并检查了不同核数据库的影响。Serpent2和标准化MCNP计算结果的比较证明,结果是相似的,因此Serpent2代码可用于VR-1反应堆堆芯计算,特别是临界预测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of the Serpent2 code for the VR-1 reactor core calculation
The VR-1 reactor core safety characteristics calculations are performed by standardized MCNP code, however due to license requirements, it is desired to replace it by the Serpent2 code. In order to do that, Serpent2 calculation must be standardized by State office of nuclear safety. Comparison of Serpent2 and MCNP multiplication factors for several reactor cores is presented to demonstrate the capability and accuracy of Serpent2 results. In addition to this, Serpent2 calculation setup is tested and the impact of different nuclear data libraries is examined. The comparison of results from Serpent2 and standardized MCNP calculation proved that results are similar and therefore the Serpent2 code can be used for the VR-1 reactor core calculations, especially for criticality predictions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信