中压杆式安装设备的防雷保护

Mandri van der Mescht, Christo van der Mescht, W. D. van Schalkwyk
{"title":"中压杆式安装设备的防雷保护","authors":"Mandri van der Mescht, Christo van der Mescht, W. D. van Schalkwyk","doi":"10.1109/ICLP56858.2022.9942627","DOIUrl":null,"url":null,"abstract":"Lightning causes numerous equipment failures which include transformers, fuses and surge arresters at pole-mount installations. Surge arresters are installed to protect equipment against lightning damage however, fuses and transformers still fail due to surge arrester failures, inadequate earthing configurations and high soil resistivity. Surge arrester failures occur due to high lightning density and high amplitude lightning strikes to the Medium Voltage overhead networks. This paper recommends an alternative network and earthing configuration to minimize surge arrester, transformer and fuse failures at Medium Voltage pole-mount installations.","PeriodicalId":403323,"journal":{"name":"2022 36th International Conference on Lightning Protection (ICLP)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Protection of Medium Voltage Pole-mount Installations Against Lightning\",\"authors\":\"Mandri van der Mescht, Christo van der Mescht, W. D. van Schalkwyk\",\"doi\":\"10.1109/ICLP56858.2022.9942627\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lightning causes numerous equipment failures which include transformers, fuses and surge arresters at pole-mount installations. Surge arresters are installed to protect equipment against lightning damage however, fuses and transformers still fail due to surge arrester failures, inadequate earthing configurations and high soil resistivity. Surge arrester failures occur due to high lightning density and high amplitude lightning strikes to the Medium Voltage overhead networks. This paper recommends an alternative network and earthing configuration to minimize surge arrester, transformer and fuse failures at Medium Voltage pole-mount installations.\",\"PeriodicalId\":403323,\"journal\":{\"name\":\"2022 36th International Conference on Lightning Protection (ICLP)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 36th International Conference on Lightning Protection (ICLP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLP56858.2022.9942627\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 36th International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP56858.2022.9942627","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

雷电引起许多设备故障,包括变压器、熔断器和避雷器。安装避雷器是为了保护设备免受雷击损坏,然而,由于避雷器故障、接地配置不充分和土壤电阻率高,熔断器和变压器仍然会失效。中压架空电网因雷电密度大、雷击幅度大而发生避雷器故障。本文推荐了一种替代网络和接地配置,以尽量减少中压杆安装时避雷器,变压器和熔断器的故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Protection of Medium Voltage Pole-mount Installations Against Lightning
Lightning causes numerous equipment failures which include transformers, fuses and surge arresters at pole-mount installations. Surge arresters are installed to protect equipment against lightning damage however, fuses and transformers still fail due to surge arrester failures, inadequate earthing configurations and high soil resistivity. Surge arrester failures occur due to high lightning density and high amplitude lightning strikes to the Medium Voltage overhead networks. This paper recommends an alternative network and earthing configuration to minimize surge arrester, transformer and fuse failures at Medium Voltage pole-mount installations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信