厚生物样品的三维相位成像(会议报告)

Regina Eckert, Michael Chen, Li-Hao Yeh, L. Waller
{"title":"厚生物样品的三维相位成像(会议报告)","authors":"Regina Eckert, Michael Chen, Li-Hao Yeh, L. Waller","doi":"10.1117/12.2516567","DOIUrl":null,"url":null,"abstract":"Phase imaging provides quantitative structural data about biological samples as an alternative or complementary contrast method to the functional information given by fluorescence imaging. In certain cases, fluorescence imaging is undesirable because it may harm the development of living cells or add time and complexity to imaging pipelines. However, current 3D phase reconstruction methods, such as optical diffraction tomography [1], are often limited to a single-scattering approximation. This limits the amount of scattering that such 3D reconstruction algorithms can successfully handle, and therefore effectively limits the sample thickness that can be successfully reconstructed. More recent methods such as 3D Fourier ptychographic microscopy (FPM) have used intensity-only images combined with multiple-scattering models in order to reconstruct 3D volumes [2]. In practice, however, continuous biological samples on the order of 100 um thick are not well-reconstructed by 3D FPM, due to a lack of diverse information across the volume which creates an ill-posed inverse problem. To mitigate this, we introduce simultaneous detection coding in the form of pupil control to the 3D FPM capture scheme. Simple pupil coding schemes enabled us to capture diverse information across our volume. In concert with a beam propagation model that takes into account multiple scattering, this combination of illumination- and detection-side coding allows us to more stably reconstruct 3D phase for larger-scale biological samples.\n\n[1] E. Wolf, “Three-dimensional structure determination of semi-transparent objects from holographic data,” Opt. Commun. 1, 153–156 (1969). \n[2] L. Tian and L. Waller, “3D intensity and phase imaging from light field measurements in an LED array microscope,” Optica, 2, 104-111 (2015).","PeriodicalId":237104,"journal":{"name":"Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XXVI","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"3D phase imaging for thick biological samples (Conference Presentation)\",\"authors\":\"Regina Eckert, Michael Chen, Li-Hao Yeh, L. Waller\",\"doi\":\"10.1117/12.2516567\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Phase imaging provides quantitative structural data about biological samples as an alternative or complementary contrast method to the functional information given by fluorescence imaging. In certain cases, fluorescence imaging is undesirable because it may harm the development of living cells or add time and complexity to imaging pipelines. However, current 3D phase reconstruction methods, such as optical diffraction tomography [1], are often limited to a single-scattering approximation. This limits the amount of scattering that such 3D reconstruction algorithms can successfully handle, and therefore effectively limits the sample thickness that can be successfully reconstructed. More recent methods such as 3D Fourier ptychographic microscopy (FPM) have used intensity-only images combined with multiple-scattering models in order to reconstruct 3D volumes [2]. In practice, however, continuous biological samples on the order of 100 um thick are not well-reconstructed by 3D FPM, due to a lack of diverse information across the volume which creates an ill-posed inverse problem. To mitigate this, we introduce simultaneous detection coding in the form of pupil control to the 3D FPM capture scheme. Simple pupil coding schemes enabled us to capture diverse information across our volume. In concert with a beam propagation model that takes into account multiple scattering, this combination of illumination- and detection-side coding allows us to more stably reconstruct 3D phase for larger-scale biological samples.\\n\\n[1] E. Wolf, “Three-dimensional structure determination of semi-transparent objects from holographic data,” Opt. Commun. 1, 153–156 (1969). \\n[2] L. Tian and L. Waller, “3D intensity and phase imaging from light field measurements in an LED array microscope,” Optica, 2, 104-111 (2015).\",\"PeriodicalId\":237104,\"journal\":{\"name\":\"Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XXVI\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XXVI\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2516567\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XXVI","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2516567","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

相位成像提供了关于生物样品的定量结构数据,作为荧光成像给出的功能信息的替代或补充对比方法。在某些情况下,荧光成像是不可取的,因为它可能损害活细胞的发育或增加成像管道的时间和复杂性。然而,目前的三维相位重建方法,如光学衍射层析成像[1],往往局限于单散射近似。这限制了这种3D重建算法能够成功处理的散射量,从而有效地限制了能够成功重建的样本厚度。最近的方法,如3D傅里叶平面显微镜(FPM),使用仅强度图像与多次散射模型相结合,以重建三维体积[2]。然而,在实践中,由于在整个体积中缺乏不同的信息,从而产生不适定逆问题,因此,100微米厚的连续生物样品不能通过3D FPM很好地重建。为了缓解这一问题,我们在3D FPM捕获方案中引入了瞳孔控制形式的同步检测编码。简单的瞳孔编码方案使我们能够在整个体量中捕获各种信息。与考虑多次散射的光束传播模型相一致,这种照明侧和检测侧编码的组合使我们能够更稳定地重建大规模生物样品的3D相位E. Wolf,“利用全息数据确定半透明物体的三维结构”,《光学学报》,1,153 - 156(1969)。[10]王晓明,王晓明,“基于LED阵列显微镜的三维光场成像研究”,光学学报,29(2):444 - 444(2015)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
3D phase imaging for thick biological samples (Conference Presentation)
Phase imaging provides quantitative structural data about biological samples as an alternative or complementary contrast method to the functional information given by fluorescence imaging. In certain cases, fluorescence imaging is undesirable because it may harm the development of living cells or add time and complexity to imaging pipelines. However, current 3D phase reconstruction methods, such as optical diffraction tomography [1], are often limited to a single-scattering approximation. This limits the amount of scattering that such 3D reconstruction algorithms can successfully handle, and therefore effectively limits the sample thickness that can be successfully reconstructed. More recent methods such as 3D Fourier ptychographic microscopy (FPM) have used intensity-only images combined with multiple-scattering models in order to reconstruct 3D volumes [2]. In practice, however, continuous biological samples on the order of 100 um thick are not well-reconstructed by 3D FPM, due to a lack of diverse information across the volume which creates an ill-posed inverse problem. To mitigate this, we introduce simultaneous detection coding in the form of pupil control to the 3D FPM capture scheme. Simple pupil coding schemes enabled us to capture diverse information across our volume. In concert with a beam propagation model that takes into account multiple scattering, this combination of illumination- and detection-side coding allows us to more stably reconstruct 3D phase for larger-scale biological samples. [1] E. Wolf, “Three-dimensional structure determination of semi-transparent objects from holographic data,” Opt. Commun. 1, 153–156 (1969). [2] L. Tian and L. Waller, “3D intensity and phase imaging from light field measurements in an LED array microscope,” Optica, 2, 104-111 (2015).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信