一种用于睡眠障碍诊断的远程医疗背心的设计——初步分析

Jakub Drzazga
{"title":"一种用于睡眠障碍诊断的远程医疗背心的设计——初步分析","authors":"Jakub Drzazga","doi":"10.1515/ipc-2018-0004","DOIUrl":null,"url":null,"abstract":"Abstract This paper presents the components of a sleep apnea analysis device that have been evaluated for diagnosis suitability and expected difficulties. The medical background and statistics of sleep apnea are presented. Work related to the topic is then discussed. A description of the system components follows: ECG, respiratory effort, nasal flow and pulse oximetry. Problems expected with all of these measurements are then outlined both from the methodological and electronic perspective. The main difficulties identified are the necessity to maintain the exact location of the sensors on the patient’s body and vulnerability of the sensors to variations of the environmental conditions. Challenges on the electronic aspect are then discussed, which are mainly caused by the need of measuring small signals (noise, interference) and compensation of the sensors’ nonlinearity. Power supply design in the context of the measurement accuracy is also considered followed by an evaluation of the impact of telemedical function presence. The paper ends with a summary and conclusions.","PeriodicalId":271906,"journal":{"name":"Image Processing & Communications","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design of a Telemedical Vest for Sleep Disorder Diagnosis - A Preliminary Analysis\",\"authors\":\"Jakub Drzazga\",\"doi\":\"10.1515/ipc-2018-0004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This paper presents the components of a sleep apnea analysis device that have been evaluated for diagnosis suitability and expected difficulties. The medical background and statistics of sleep apnea are presented. Work related to the topic is then discussed. A description of the system components follows: ECG, respiratory effort, nasal flow and pulse oximetry. Problems expected with all of these measurements are then outlined both from the methodological and electronic perspective. The main difficulties identified are the necessity to maintain the exact location of the sensors on the patient’s body and vulnerability of the sensors to variations of the environmental conditions. Challenges on the electronic aspect are then discussed, which are mainly caused by the need of measuring small signals (noise, interference) and compensation of the sensors’ nonlinearity. Power supply design in the context of the measurement accuracy is also considered followed by an evaluation of the impact of telemedical function presence. The paper ends with a summary and conclusions.\",\"PeriodicalId\":271906,\"journal\":{\"name\":\"Image Processing & Communications\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Image Processing & Communications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/ipc-2018-0004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Image Processing & Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/ipc-2018-0004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

摘要:本文介绍了一种睡眠呼吸暂停分析装置的组成部分,对其诊断适用性和预期困难进行了评估。本文介绍了睡眠呼吸暂停的医学背景和统计数据。然后讨论与主题相关的工作。系统组件的描述如下:心电图,呼吸力度,鼻流量和脉搏血氧仪。然后从方法学和电子学的角度概述了所有这些测量可能出现的问题。确定的主要困难是必须保持传感器在患者身体上的确切位置,以及传感器对环境条件变化的脆弱性。然后讨论了电子方面的挑战,主要是由于需要测量小信号(噪声、干扰)和补偿传感器的非线性。在测量精度的背景下,还考虑了电源设计,随后评估了远程医疗功能存在的影响。论文最后进行了总结和结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of a Telemedical Vest for Sleep Disorder Diagnosis - A Preliminary Analysis
Abstract This paper presents the components of a sleep apnea analysis device that have been evaluated for diagnosis suitability and expected difficulties. The medical background and statistics of sleep apnea are presented. Work related to the topic is then discussed. A description of the system components follows: ECG, respiratory effort, nasal flow and pulse oximetry. Problems expected with all of these measurements are then outlined both from the methodological and electronic perspective. The main difficulties identified are the necessity to maintain the exact location of the sensors on the patient’s body and vulnerability of the sensors to variations of the environmental conditions. Challenges on the electronic aspect are then discussed, which are mainly caused by the need of measuring small signals (noise, interference) and compensation of the sensors’ nonlinearity. Power supply design in the context of the measurement accuracy is also considered followed by an evaluation of the impact of telemedical function presence. The paper ends with a summary and conclusions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信