John Ramoul, Gayan Watthewaduge, A. Callegaro, B. Nahid-Mobarakeh, A. Baronian, A. Emadi
{"title":"电动起降飞机电力推进用永磁同步电机断相及相间短路故障分析","authors":"John Ramoul, Gayan Watthewaduge, A. Callegaro, B. Nahid-Mobarakeh, A. Baronian, A. Emadi","doi":"10.1109/IECON48115.2021.9589890","DOIUrl":null,"url":null,"abstract":"This paper analyzes permanent magnet synchronous machines (PMSM) under open phase and phase-to-phase fault conditions within an electric vertical take-off and landing (eVTOL) aircraft. The development of a detailed mathematical model for a PMSM under the open phase fault (OPF) and phaseto-phase short circuit fault (P2PSCF) conditions are presented and implemented in MATLAB/Simulink along with its results within a ring bus electrical distribution system (REDS) for an eVTOL is presented. The behavior of both faults is investigated. Fault-tolerant control (FTC) is applied during the post-fault operation, and the copper losses and torque ripple are analyzed. Two fault mitigation techniques, 1) disabling the inverter (FTC1) and 2) creating a virtual neutral point (FTC2) with the inverter, are introduced for the P2PSCF. FTC1 had a peak-to-peak torque ripple of 309Nm with 1.55kW reduction of copper losses. FTC2 was found to respond faster than FTC1 and generated 157Nm peak-to-peak torque ripple. The OPF FTC was analyzed where only current references are changed for the same PI controller structure to enable a fail-operational state for the eVTOL. The OPF FTC achieved 348Nm peak to peak torque ripple compared to 371Nm to pre-fault conditions.","PeriodicalId":443337,"journal":{"name":"IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of Open Phase and Phase-to-Phase Short Circuit Fault of PMSM for Electrical Propulsion in an eVTOL\",\"authors\":\"John Ramoul, Gayan Watthewaduge, A. Callegaro, B. Nahid-Mobarakeh, A. Baronian, A. Emadi\",\"doi\":\"10.1109/IECON48115.2021.9589890\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper analyzes permanent magnet synchronous machines (PMSM) under open phase and phase-to-phase fault conditions within an electric vertical take-off and landing (eVTOL) aircraft. The development of a detailed mathematical model for a PMSM under the open phase fault (OPF) and phaseto-phase short circuit fault (P2PSCF) conditions are presented and implemented in MATLAB/Simulink along with its results within a ring bus electrical distribution system (REDS) for an eVTOL is presented. The behavior of both faults is investigated. Fault-tolerant control (FTC) is applied during the post-fault operation, and the copper losses and torque ripple are analyzed. Two fault mitigation techniques, 1) disabling the inverter (FTC1) and 2) creating a virtual neutral point (FTC2) with the inverter, are introduced for the P2PSCF. FTC1 had a peak-to-peak torque ripple of 309Nm with 1.55kW reduction of copper losses. FTC2 was found to respond faster than FTC1 and generated 157Nm peak-to-peak torque ripple. The OPF FTC was analyzed where only current references are changed for the same PI controller structure to enable a fail-operational state for the eVTOL. The OPF FTC achieved 348Nm peak to peak torque ripple compared to 371Nm to pre-fault conditions.\",\"PeriodicalId\":443337,\"journal\":{\"name\":\"IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"78 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON48115.2021.9589890\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON48115.2021.9589890","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of Open Phase and Phase-to-Phase Short Circuit Fault of PMSM for Electrical Propulsion in an eVTOL
This paper analyzes permanent magnet synchronous machines (PMSM) under open phase and phase-to-phase fault conditions within an electric vertical take-off and landing (eVTOL) aircraft. The development of a detailed mathematical model for a PMSM under the open phase fault (OPF) and phaseto-phase short circuit fault (P2PSCF) conditions are presented and implemented in MATLAB/Simulink along with its results within a ring bus electrical distribution system (REDS) for an eVTOL is presented. The behavior of both faults is investigated. Fault-tolerant control (FTC) is applied during the post-fault operation, and the copper losses and torque ripple are analyzed. Two fault mitigation techniques, 1) disabling the inverter (FTC1) and 2) creating a virtual neutral point (FTC2) with the inverter, are introduced for the P2PSCF. FTC1 had a peak-to-peak torque ripple of 309Nm with 1.55kW reduction of copper losses. FTC2 was found to respond faster than FTC1 and generated 157Nm peak-to-peak torque ripple. The OPF FTC was analyzed where only current references are changed for the same PI controller structure to enable a fail-operational state for the eVTOL. The OPF FTC achieved 348Nm peak to peak torque ripple compared to 371Nm to pre-fault conditions.