A. Sadeghpour, M. Shahrabi, H. Bakhshandeh, N. Naderi
{"title":"368名伊朗健康人超声心动图正常值","authors":"A. Sadeghpour, M. Shahrabi, H. Bakhshandeh, N. Naderi","doi":"10.5812/acvi.15662","DOIUrl":null,"url":null,"abstract":"Background: Echocardiography is widely used to diagnose or exclude cardiac disease. The reports on reference values based on an Asian population are limited. Objectives: We conducted a study to determine normal values for two-dimensional, M-mode, and Doppler echocardiographic measurements and evaluate the relationship between these parameters and age and gender in a large, healthy Iranian population. Patients and Methods: Among a total of 400 volunteers in a cross-sectional study, 368 healthy individuals aged between 30 and 70 years [171 males at a mean age of 47.6 (9.9) and 197 females at a mean age of 47.6 (9.5)] were enrolled. Standard comprehensive transthoracic echocardiography (TTE) was performed based on the guidelines of the American Society of Echocardiography. The normal limits are presented as mean (SD) and are also indexed to body surface area (BSA). Results: There was no significant difference between the men and women regarding left ventricular (LV) ejection fraction (57.97% vs. 57.99%). The mean of LV end-diastolic diameter (LVEDD), LV end-systolic diameter (LVESD), interventricular septum (IVS), posterior wall (PW) thickness, and right ventricular diastolic diameter (RVDd) was significantly greater in the men than in the women. However, there was an inverse relationship when LVEDD, RVDd, and left atrial (LA) diameter and area were indexed to BSA. There was no significant difference in the mean of LA area between the males and females (14.28 vs. 13.6 cm2). The LV diastolic parameters correlated negatively with age. A peakE /A velocity ratio <1 was found in the subjects over 50 years old. The mean of all the measurements in our study was less than the reference values in the published guidelines. Conclusions: Our study, the first and largest investigation of its kind, provides reference values for the echocardiographic evaluation of the cardiac size and function of Iranian healthy individuals. The mean of our measurements was significantly less than that reported in the published guidelines.","PeriodicalId":429543,"journal":{"name":"Archives of Cardiovascular Imaging","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Normal echocardiographic values of 368 Iranian healthy subjects\",\"authors\":\"A. Sadeghpour, M. Shahrabi, H. Bakhshandeh, N. Naderi\",\"doi\":\"10.5812/acvi.15662\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Echocardiography is widely used to diagnose or exclude cardiac disease. The reports on reference values based on an Asian population are limited. Objectives: We conducted a study to determine normal values for two-dimensional, M-mode, and Doppler echocardiographic measurements and evaluate the relationship between these parameters and age and gender in a large, healthy Iranian population. Patients and Methods: Among a total of 400 volunteers in a cross-sectional study, 368 healthy individuals aged between 30 and 70 years [171 males at a mean age of 47.6 (9.9) and 197 females at a mean age of 47.6 (9.5)] were enrolled. Standard comprehensive transthoracic echocardiography (TTE) was performed based on the guidelines of the American Society of Echocardiography. The normal limits are presented as mean (SD) and are also indexed to body surface area (BSA). Results: There was no significant difference between the men and women regarding left ventricular (LV) ejection fraction (57.97% vs. 57.99%). The mean of LV end-diastolic diameter (LVEDD), LV end-systolic diameter (LVESD), interventricular septum (IVS), posterior wall (PW) thickness, and right ventricular diastolic diameter (RVDd) was significantly greater in the men than in the women. However, there was an inverse relationship when LVEDD, RVDd, and left atrial (LA) diameter and area were indexed to BSA. There was no significant difference in the mean of LA area between the males and females (14.28 vs. 13.6 cm2). The LV diastolic parameters correlated negatively with age. A peakE /A velocity ratio <1 was found in the subjects over 50 years old. The mean of all the measurements in our study was less than the reference values in the published guidelines. Conclusions: Our study, the first and largest investigation of its kind, provides reference values for the echocardiographic evaluation of the cardiac size and function of Iranian healthy individuals. The mean of our measurements was significantly less than that reported in the published guidelines.\",\"PeriodicalId\":429543,\"journal\":{\"name\":\"Archives of Cardiovascular Imaging\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Cardiovascular Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5812/acvi.15662\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Cardiovascular Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5812/acvi.15662","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11
摘要
背景:超声心动图被广泛用于诊断或排除心脏疾病。基于亚洲人口的参考值报告是有限的。目的:我们进行了一项研究,以确定二维、m型和多普勒超声心动图测量的正常值,并评估这些参数与伊朗大量健康人群的年龄和性别之间的关系。患者和方法:在一项横断面研究中,共有400名志愿者入选368名年龄在30 - 70岁之间的健康个体[171名男性,平均年龄47.6(9.9)岁,197名女性,平均年龄47.6(9.5)岁]。标准全面经胸超声心动图(TTE)是根据美国超声心动图学会的指南进行的。正常极限以平均值(SD)表示,也与体表面积(BSA)相关。结果:男性和女性左室射血分数无显著差异(57.97% vs. 57.99%)。男性左室舒张末期内径(LVEDD)、左室收缩末期内径(LVESD)、室间隔(IVS)、后壁(PW)厚度和右室舒张末期内径(RVDd)的平均值明显大于女性。然而,当LVEDD、RVDd和左房(LA)直径和面积与BSA指数呈反比关系。男性和女性的平均LA面积没有显著差异(14.28 cm2比13.6 cm2)。左室舒张参数与年龄呈负相关。在50岁以上的受试者中发现峰值/流速比<1。我们研究中所有测量值的平均值小于已发表的指南中的参考值。结论:本研究为伊朗健康人心脏大小和功能的超声心动图评价提供了参考价值。我们测量的平均值明显小于已发表的指南中报道的平均值。
Normal echocardiographic values of 368 Iranian healthy subjects
Background: Echocardiography is widely used to diagnose or exclude cardiac disease. The reports on reference values based on an Asian population are limited. Objectives: We conducted a study to determine normal values for two-dimensional, M-mode, and Doppler echocardiographic measurements and evaluate the relationship between these parameters and age and gender in a large, healthy Iranian population. Patients and Methods: Among a total of 400 volunteers in a cross-sectional study, 368 healthy individuals aged between 30 and 70 years [171 males at a mean age of 47.6 (9.9) and 197 females at a mean age of 47.6 (9.5)] were enrolled. Standard comprehensive transthoracic echocardiography (TTE) was performed based on the guidelines of the American Society of Echocardiography. The normal limits are presented as mean (SD) and are also indexed to body surface area (BSA). Results: There was no significant difference between the men and women regarding left ventricular (LV) ejection fraction (57.97% vs. 57.99%). The mean of LV end-diastolic diameter (LVEDD), LV end-systolic diameter (LVESD), interventricular septum (IVS), posterior wall (PW) thickness, and right ventricular diastolic diameter (RVDd) was significantly greater in the men than in the women. However, there was an inverse relationship when LVEDD, RVDd, and left atrial (LA) diameter and area were indexed to BSA. There was no significant difference in the mean of LA area between the males and females (14.28 vs. 13.6 cm2). The LV diastolic parameters correlated negatively with age. A peakE /A velocity ratio <1 was found in the subjects over 50 years old. The mean of all the measurements in our study was less than the reference values in the published guidelines. Conclusions: Our study, the first and largest investigation of its kind, provides reference values for the echocardiographic evaluation of the cardiac size and function of Iranian healthy individuals. The mean of our measurements was significantly less than that reported in the published guidelines.