用无损数据压缩确定有噪声心电图的信噪比

A. Pulavskyi, S. Krivenko, L. Kryvenko
{"title":"用无损数据压缩确定有噪声心电图的信噪比","authors":"A. Pulavskyi, S. Krivenko, L. Kryvenko","doi":"10.1109/MECO.2019.8760294","DOIUrl":null,"url":null,"abstract":"A numerical method for determining the signal-to-noise ratio (SNR) in electrocardiograms (ECG), distorted by various types of additive noise, is proposed. It is based on the calculation of the compression ratio (CRn) of an ECG fragment of 10 seconds duration. The functional dependences of SNR on CRn for ECG distorted by electrode motion, muscle artefacts and mixed noise, were found, and they are exponential. The values of root mean square error (RMSE) for such dependencies were 4.24 dB, 3.57 dB и 3.33 dB accordingly for SNR in range −10…45 dB. It is proved that the inclusion of heart rate (HR) in the model reduces the error by 0.6-0.8 dB. The present approach is based on the standard library zlib and is recommended for use in portative mobile systems.","PeriodicalId":141324,"journal":{"name":"2019 8th Mediterranean Conference on Embedded Computing (MECO)","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of the Signal-to-Noise Ratio for Noisy Electrocardiogram Using Lossless Data Compression\",\"authors\":\"A. Pulavskyi, S. Krivenko, L. Kryvenko\",\"doi\":\"10.1109/MECO.2019.8760294\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A numerical method for determining the signal-to-noise ratio (SNR) in electrocardiograms (ECG), distorted by various types of additive noise, is proposed. It is based on the calculation of the compression ratio (CRn) of an ECG fragment of 10 seconds duration. The functional dependences of SNR on CRn for ECG distorted by electrode motion, muscle artefacts and mixed noise, were found, and they are exponential. The values of root mean square error (RMSE) for such dependencies were 4.24 dB, 3.57 dB и 3.33 dB accordingly for SNR in range −10…45 dB. It is proved that the inclusion of heart rate (HR) in the model reduces the error by 0.6-0.8 dB. The present approach is based on the standard library zlib and is recommended for use in portative mobile systems.\",\"PeriodicalId\":141324,\"journal\":{\"name\":\"2019 8th Mediterranean Conference on Embedded Computing (MECO)\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 8th Mediterranean Conference on Embedded Computing (MECO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MECO.2019.8760294\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 8th Mediterranean Conference on Embedded Computing (MECO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MECO.2019.8760294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种确定被各种加性噪声失真的心电图信噪比的数值方法。它是基于对持续时间为10秒的心电片段的压缩比(CRn)的计算。发现受电极运动、肌肉伪影和混合噪声畸变的心电信号的信噪比与CRn呈指数关系。在- 10…45 dB的信噪比范围内,这些相关性的均方根误差(RMSE)值分别为4.24 dB, 3.57 dB和3.33 dB。实验证明,在模型中加入心率(HR)可以使误差降低0.6 ~ 0.8 dB。目前的方法是基于标准库zlib,并推荐用于便携式移动系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of the Signal-to-Noise Ratio for Noisy Electrocardiogram Using Lossless Data Compression
A numerical method for determining the signal-to-noise ratio (SNR) in electrocardiograms (ECG), distorted by various types of additive noise, is proposed. It is based on the calculation of the compression ratio (CRn) of an ECG fragment of 10 seconds duration. The functional dependences of SNR on CRn for ECG distorted by electrode motion, muscle artefacts and mixed noise, were found, and they are exponential. The values of root mean square error (RMSE) for such dependencies were 4.24 dB, 3.57 dB и 3.33 dB accordingly for SNR in range −10…45 dB. It is proved that the inclusion of heart rate (HR) in the model reduces the error by 0.6-0.8 dB. The present approach is based on the standard library zlib and is recommended for use in portative mobile systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信